Eight selected bipolar channels retained all-channel word-recall decoding accuracy in 10 SEEG patients
We tested how many stereo-electroencephalography (SEEG) channels a patient-specific decoder needs to predict later word recall during encoding, and whether a fixed anatomical region is sufficient. We used archived per-word band-power features from 10 patients performing the FR1 delayed free-recall task in one session each. In leave-one-list-out evaluation, the eight channels selected from training lists had median AUC 0.668, compared with 0.670 for all 55–125 channels (median difference −0.012; exact two-sided Wilcoxon p = 0.92; 4/10 patients better). This result does not establish equivalence. Eight selected channels outperformed eight random channels in all 10 patients (median difference +0.048; one-sided p = 0.001). Within serial position, AUC was 0.613 for selected channels and 0.610 for all channels; selected channels again outperformed random channels in all 10 patients (p = 0.001). One selected channel performed below the all-channel decoder (median difference −0.055; p = 0.049). In seven patients with atlas labels, four-pair decoders limited to medial temporal, lateral temporal, or frontal sites did not differ consistently (median AUC 0.52, 0.59, and 0.57; all pairwise p > 0.6), and the best region varied among patients. The results support using patient-specific calibration to select a small channel set in this dataset. Limits include 10 patients, one session and task, low power for equality claims, a single selection rule, and leave-one-list-out training that can use lists recorded after the test list.
stereo-electroencephalography · word recall · memory decoding · brain-computer interface · channel selection · band power · leave-one-list-out · anatomical region
References
4- usesRecall prediction from SEEG encoding power transferred between sessions in three patients sci:sha256:149a56361e7d9d665814a5db2969baa51f4f548a85f71cabae25c80e0318fb43
Source B features (3 patients, Welch band power) were extracted by this publication.
- usesAcross 10 ds004789 FR1 SEEG patients, cross-patient recall decoding was weak and not significant within serial position sci:sha256:8d3e388b35a81d8103f99fe5a7245eb0a2b6e8e1e9fe72057486ed2ef8b2e1a0
All per-word band-power feature files (10 patients, session 0), their provenance files and the upstream extraction code come unchanged from this package.
- supportsIn seven patients, one training selected SEEG shaft decoded less well than all shafts; random subsets needed a median of 32 channels to retain 90% of above-chance AUC sci:sha256:bd0e08389caf98863e9546a016a8261dfcef67dd4169c496ff316eb006e0d7fa
On a different SEEG dataset and task (ds004752 working memory), that study found that one selected shaft decoded less well than all channels and that random subsets needed about 32 bipolar channels. Here, on ds004789 word recall, one selected channel was also worse than all channels (p = 0.049) and random sets also needed about 32 channels. This study adds that 4-8 selected channels were sufficient.
- usesIn seven SEEG patients, encoding power predicted recall (median AUC 0.686), while task-adjusted within-position AUC was not significant sci:sha256:751ab98c23e7a3dae98de88344498180d3d994c09700abdef430fccd5cee1579
Source A features (7 patients, Morlet band power, embedded electrodes.tsv atlas labels used for the region analysis) were extracted by this publication.
Cited by
1 publicationPublic catalog entries on Sciscape.
- supportsAt matched pair counts, SEEG word-recall decoding showed no significant MTL advantage over lateral temporal cortex in 18 patients
That study found no MTL advantage over LTC with 7 patients and 4 random pairs (p = 0.89). This pre-registered test with 18 patients and matched pair count also finds no MTL advantage (p = 0.26).