In seven patients, one training selected SEEG shaft decoded less well than all shafts; random subsets needed a median of 32 channels to retain 90% of above-chance AUC
This study asks how decoding performance changes when a band-power decoder uses fewer intracranial channels or only one depth shaft. Using session 1 from seven patients in OpenNeuro ds004752 v1.0.1, we compared maintenance versus fixation (task phase) with verbal working-memory load (8 vs 4 letters). Shrinkage LDA was evaluated with trial-grouped, repeated five-fold cross-validation. The median AUC across all SEEG channels was 0.89 for phase and 0.82 for load. One shaft selected within training data had median AUCs of 0.80 and 0.61; it scored below all channels in 7/7 patients for phase (p = 0.016) and 6/7 for load (p = 0.031). It retained a median 0.81 and 0.45 of above-chance AUC, respectively. The best shaft chosen after seeing test data had median load AUC 0.79, showing that this post-hoc choice overstates performance expected from training-only selection. Random channel subsets needed a median of 32 bipolar channels (range 8–56 for phase; 16–56 for load) to retain 90% of above-chance AUC. Eight training-selected channels performed better than eight random channels, but remained below all channels for phase. All SEEG channels did not significantly outperform 19 scalp EEG channels, nor did eight random SEEG channels outperform eight scalp EEG channels. Results are limited to seven clinical patients, one session each, few trials, and a linear decoder on band power. Load decoding varied substantially; sub-01 and sub-02 were not above the null. Phase decoding may reflect slow non-specific changes such as arousal or eye movement as well as memory maintenance. The package includes original analysis code, results, derived features, and raw-file hashes.
SEEG · intracranial EEG · working memory · channel selection · brain-computer interface · band power · shrinkage LDA · ROC AUC · OpenNeuro
References
4- supportsFour SEEG subjects decoded task phase better than memory load or probe match across reference schemes sci:sha256:341751ce85385bec3d9952e1c6f69998b53f06f3664b87da2c409f44289ec276
With a different subject set (7 subjects, 3 overlapping) and a trial-grouped CV, maintenance vs fixation decoded from all bipolar SEEG channels at median AUC 0.89 (range 0.78-0.94), in agreement with its AUC 0.81-0.85 for task phase.
- usesIn one session from seven patients, SEEG decoded working-memory load but did not outperform scalp EEG sci:sha256:50e06bf2c1d8b22ce11eb33941327223a3b3dcbf79727353693e28fcfad0f0ea
We used its per-trial bipolar SEEG and scalp EEG band-power features (fixation and maintenance windows, sub-01 to sub-07, session 1, with raw-file SHA-256 provenance) unchanged as the input of all analyses.
- usesdoi:10.18112/openneuro.ds004752.v1.0.1
The raw source is documented as OpenNeuro ds004752 v1.0.1; the analysis used session 1 of sub-01 to sub-07.
- doi:10.7554/eLife.78677
Cited by
5 publicationsPublic catalog entries on Sciscape.
- supportsIn 18 FR1 patients, an 8-channel SEEG decoder retained 83% of above-chance AUC but scored below the all-channel decoder
In a different dataset and task (ds004789 word recall, 18 patients), one shaft and all budgets of 1 to 32 channels also decoded less well than all channels.
- supportsFour selected SEEG shafts were non-inferior to all shafts for key-press detection, but one was not
Same direction in a second task: one training-selected shaft decoded worse than all shafts in ds004752; here one shaft was also worse for key press in ds004473.
- supportsEight selected bipolar channels retained all-channel word-recall decoding accuracy in 10 SEEG patients
On a different SEEG dataset and task (ds004752 working memory), that study found that one selected shaft decoded less well than all channels and that random subsets needed about 32 bipolar channels. Here, on ds004789 word recall, one selected channel was also worse than all channels (p = 0.049) and random sets also needed about 32 channels. This study adds that 4-8 selected channels were sufficient.
- supportsIn 8 SEEG subjects, 100-trial single-channel screening overestimated later AUC by 0.075 on average, but not after Holm correction
On a second dataset (ds004473 motor), a channel selected on training data also decoded less well than all channels (8 of 8 subjects).
- supportsSEEG load decoding improves with channel count, while training fold selection adds a small and inconsistent gain
Both studies find that small channel sets decode less well than all SEEG channels in ds004752; here for load with random and selected channel subsets.