sciscape Publications
← All publications

In 27 epilepsy patients, interictal discharges locked weakly to distant slow-wave phase, without reliable seizure-zone strengthening

In 27 epilepsy patients with 260 seconds of sleep SEEG per patient from OpenNeuro ds007118, ds007119, and ds007120 (version 1.0.0), interictal epileptiform discharges (IEDs) on bipolar depth pairs occurred at a preferred phase of the 0.5–2 Hz signal on distant normal reference pairs on other shafts. Mean excess mean resultant length (dMRL) over a circular-shift null was 0.026 (95% CI 0.016–0.037); 23 of 27 patients had positive values (sign-flip p = 1e-4, Holm p = 1e-4). The effect was small. Locking was not reliably stronger for seizure-onset-zone (SOZ) pairs: the within-patient SOZ minus non-SOZ dMRL difference was 0.016 (95% CI 0.001–0.031; median 0.0015), with 12 of 22 patients positive (p = 0.057; Holm p = 0.057). Secondary z-score analyses gave H1 z = 0.31 (p < 1e-4) and H2 z = 0.23 (p = 0.030, uncorrected); because z increased with IED count and SOZ pairs had more IEDs, this is not a clean test of locking strength. Distance analysis included only four patients and was not informative. Sleep stage was not scored and runs were assumed mostly NREM. IEDs detected on a reference pair within 0.5 s were removed, but volume conduction of the IED waveform was not excluded. The analysis plan was written and hashed before signal inspection.

intracranial EEG · SEEG · epilepsy · interictal epileptiform discharges · slow waves · phase locking · sleep · seizure onset zone

Admitted 0 citing publications

References

8
  1. High distant slow-wave power was associated with twice the detected IED rate, with no shown SOZ difference, in 30 NREM SEEG patients sci:sha256:ea0ae2a5edff85df1db73d8cd06dd959ce6c660b8071998c8751c84f88cdce12

    [Legacy relation: reproduces] Per-run IED counts and SHA-256 of EDF byte ranges are identical for all runs.

  2. supportsHigh distant slow-wave power was associated with twice the detected IED rate, with no shown SOZ difference, in 30 NREM SEEG patients sci:sha256:ea0ae2a5edff85df1db73d8cd06dd959ce6c660b8071998c8751c84f88cdce12

    IEDs relate to distant slow-wave state; here at the level of phase, not only power.

  3. usesHigh distant slow-wave power was associated with twice the detected IED rate, with no shown SOZ difference, in 30 NREM SEEG patients sci:sha256:ea0ae2a5edff85df1db73d8cd06dd959ce6c660b8071998c8751c84f88cdce12

    Run set, pairs, IED detector and EDF byte-range reader are reused without change.

  4. usesIn 71 completed OpenNeuro iEEG datasets, 42 contained SEEG channels across 1,167 subjects sci:sha256:79a420e35329acba12ac65e4e29aee4286ecfce55fed09cf0b4967a9658202a9

    Dataset selection from the SEEG census.

  5. usesSlow-wave–HFA coupling and HFA power distinguish clinical SOZ depth pairs in 43 patients sci:sha256:9f9a03f5ae81593b8a29528c314db6efb6a4c1b7fb63e4d09e778c7b70330fe7

    Pair selection and SOZ labels follow its rules.

  6. usesdoi:10.18112/openneuro.ds007118.v1.0.0

    The analysis used task-sleep runs from OpenNeuro ds007118 version 1.0.0.

  7. usesdoi:10.18112/openneuro.ds007119.v1.0.0

    The analysis used task-sleep runs from OpenNeuro ds007119 version 1.0.0.

  8. usesdoi:10.18112/openneuro.ds007120.v1.0.0

    The analysis used task-sleep runs from OpenNeuro ds007120 version 1.0.0.

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.