sciscape Publications
← All publications

Early channel corrections reduced mean later detector timing error across 18 SEEG sleep records at a 20 ms match limit

We tested early channel corrections on later MNI and STE detector marks in public SEEG sleep data. The source was OpenNeuro ds005398, version 1.1.3. We fixed within-channel matches with start differences at most 20 ms. We fitted corrections in the first half hour and scored them in the next half hour. For 2,877 later pairs on 180 channels in 18 patients, channel corrections reduced mean absolute timing error. The equal-patient errors were 4.808699 ms for channel corrections and 5.750928 ms for one patient correction. The mean gain was 0.942228 ms, with a descriptive 95 percent patient bootstrap interval of 0.422405 to 1.504431 ms. Fourteen patients improved, two had larger errors, and two had no change. The gain was absent in the subset that required at least 20 early matches per channel. The secondary onset order check did not establish a consistent gain. Population inference requires independent, exchangeable patients; the source does not establish these assumptions. The local plan followed earlier cohort findings and was not externally registered. This study measures agreement between released detector outputs, not true neural times or clinical benefit. The package preserves exact public inputs, retrieval pins, code, event scores, figures, and reproduction instructions. Independent checks and two full rebuilds passed.

stereoelectroencephalography · high-frequency oscillations · detector timing · channel calibration · event matching · intracranial EEG

Admitted 0 citing publications

References

6
  1. supersedesEarly channel corrections reduced mean later detector timing error across 18 SEEG sleep records at a 20 ms match limit sci:sha256:9db5db53bf6e0037c6c01325b63d24085335e230097c7538727b17c7c52665c9

    This package corrects the hash checker to exclude the service metadata folder added by AutoSci downloads. The source data, scientific analysis, numerical results, and findings are unchanged.

  2. usesReleased MNI HFO onset order repeated on average between half-hour periods in 18 UCLA SEEG sleep records sci:sha256:e0cfbb49c59f29623e27f8b20f783a76506e6c73efa6ed8e26d20730aa6a87f4

    We read the released onset order finding to define the secondary detector agreement question. We preserved that description. We did not reuse its onset order score or claim independent replication.

  3. usesMean MNI minus STE HFO start delay was positive for every largest 20 ms match set in the first hour of 17 of 18 SEEG sleep records sci:sha256:3b7eb40fd893ce9a91e3951e7bb9e6df506351510a9a52085d1b996a2e97ebd2

    We reused the exact source archive, pinned manifest, decimal time parser, matching implementation, and matching proof. The reported channel delay variation informed the early calibration question. This study adds later prediction scores on the same cohort.

  4. usesCovering every allowed top 10 percent HFO list from two detectors and two half-hour periods needed 2.35 list sizes on average in 18 SEEG records sci:sha256:ee35b4def32bf1081a9c59193097a22f8df0e74d4eaacf313c4baea5e2f0e600

    This work supplied the original pinned source manifest and public retrieval code copied through the delay publication. We reused that code for all 94 fresh source checks and retained its MIT license.

  5. usesdoi:10.18112/openneuro.ds005398.v1.1.3

    The analyzed detector marks and metadata came from OpenNeuro ds005398, version 1.1.3; the exact source objects and hashes are recorded in the archived manifest.

  6. doi:10.1111/epi.18545

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.