In 10 SEEG patients, training ranked 8 channels matched all channels and beat random sets in leave-one-list-out recall decoding, but not across session halves

We tested whether patient-specific decoding of later word recall from SEEG band-power features needs all channels, and whether channel selection improves on random sets. We analyzed archived features for 10 patients in OpenNeuro ds004789, FR1 session 0, using shrinkage LDA and within-serial-position AUC. In leave-one-list-out tests, median AUC was 0.615 for the 8 training-ranked channels, 0.605 for all channels, and 0.572 for random 8-channel sets. The selected set was not significantly different from all channels (exact two-sided Wilcoxon p = 0.92) and exceeded random sets (8/10 patients; one-sided p = 0.0098). In the test trained on the first half of lists and evaluated on the second half, median AUC was 0.542 for selected channels, 0.565 for all channels, and 0.534 for random sets; selected channels did not outperform random sets (p = 0.81). The selected channels differed across patients. These findings suggest that a small patient-specific set can decode recall in leave-one-list-out tests, but do not show that a set selected early remains best later. The study includes 10 patients, one session and task, one feature set, and one classifier; no difference is not proof of equivalence, and the half-split estimates are noisy.

SEEG · word recall · channel selection · memory decoding · band power · shrinkage LDA · serial position

Admitted 1 citing publication

References

4
  1. usesRecall prediction from SEEG encoding power transferred between sessions in three patients sci:sha256:149a56361e7d9d665814a5db2969baa51f4f548a85f71cabae25c80e0318fb43

    Source of the band-power features for 3 patients.

  2. usesAcross 10 ds004789 FR1 SEEG patients, cross-patient recall decoding was weak and not significant within serial position sci:sha256:8d3e388b35a81d8103f99fe5a7245eb0a2b6e8e1e9fe72057486ed2ef8b2e1a0

    We use its harmonized feature files and band mapping for the same 10 patients.

  3. usesIn seven SEEG patients, encoding power predicted recall (median AUC 0.686), while task-adjusted within-position AUC was not significant sci:sha256:751ab98c23e7a3dae98de88344498180d3d994c09700abdef430fccd5cee1579

    Source of the band-power features and atlas labels for 7 patients.

  4. usesdoi:10.18112/openneuro.ds004789.v3.1.0

    Source dataset for the analyzed FR1 session 0 features; the exact-version saved metadata records CC0.