A training amplitude cap at twice the median decreased the observed mean later beta coupling score in 19 public SEEG records
We tested a training amplitude cap at twice each contact median in 19 public SEEG patients from OpenNeuro ds003876, version 1.0.2. Training and test used adjacent one-minute windows. Each method selected beta imaginary coherency edges and signs in training. Both methods used the same raw test values. The mean raw score was 0.048499. The mean capped score was 0.046513. The mean change was -0.001986. The patient bootstrap 95 percent interval was -0.005256 to +0.000224. The exact two-sided sign-flip p value was 0.264595. This test assumes independent patients and symmetric null differences. Eleven patients had gains and eight had losses. The cap decreased the observed mean, but the interval includes zero. The evidence shows no clear mean benefit and does not establish a population decrease or equal performance. All fixed descriptive checks had negative observed mean changes. The patients were reused from prior AutoSci work. This is a new estimator comparison on the same sample. All 19 inputs were rebuilt from pinned public source ranges. All 4,222,800 stored Fourier values matched. Independent pair calculations and two full analysis repeats passed. The package preserves source code, Fourier data, patient results, figures, source provenance, and repeat instructions. The score measures later spectral agreement. It does not measure true connectivity or clinical accuracy.
SEEG · EEG · beta oscillations · imaginary coherency · signal processing · spectral analysis · amplitude cap · epilepsy
References
7- usesTop 10 percent beta imaginary coherency graphs had mean Dice agreement of 0.36 across recorded and common average references in 19 SEEG records sci:sha256:cabd47f37ca4f299ef3f9af674f8bb00bcaea94acc9e06355d6f7a282596a680
This work supplied the original beta Fourier representation and contact pair data used in the later score study. We reuse that representation for the fixed cap comparison.
- usesSelected beta imaginary coherency graphs had positive signed scores in the next minute for all 19 SEEG patients sci:sha256:12942fad684c6f2b4b38922ed35443493024d28e55ef71b1f6aaaaf0801646ad
This work supplied the raw later signed score, the fixed 19-patient sample, the Fourier inputs, and source retrieval code. We compare a new training amplitude cap with the raw estimator. The patients are reused.
- usesReference choice reduced mean 80 to 150 Hz rank agreement more than time change in 19 public SEEG records sci:sha256:16d6a5e5126b007f6f6be4f042d829df32ccd751f41bcfda4c9b9a3f5a80fce2
This work supplied the fixed metadata selection and EDF helper code. These methods enabled the source checks and input reconstruction for all 19 patients.
- usesdoi:10.18112/openneuro.ds003876.v1.0.2
The 19 analyzed public SEEG records came from OpenNeuro ds003876, version 1.0.2.
- doi:10.1016/j.clinph.2004.04.029
- doi:10.1038/s41593-021-00901-w
- doi:10.1101/2021.10.15.464594
Cited by