sciscape Publications
← All publications

In 8 ds005448 SEEG patients, white-matter-only contacts had no N1 labels; boundary and gray-matter contacts showed no consistent difference

We examined whether SEEG recording contacts in or near white matter (WM) differ from gray-matter (GM) contacts in expert-checked N1 cortico-cortical evoked potentials (CCEPs), using OpenNeuro ds005448 v1.0.0 (STReEF): 8 patients, 11 runs, and clinical single pulses at 1–2 mA. Dataset tissue flags classified contacts as WM only, GM only, both (MIX; gray-white boundary), or neither (NONE). All 219 WM-only depth contacts were excluded for every stimulated pair in all 8 patients and 11 runs (9,253/9,253 entries), so this dataset has no N1 labels at WM-only recording contacts. At distances of at least 10 mm, the comparison therefore used MIX as a proxy for near-WM contacts, not as WM contacts, and GM contacts: 17,712 units, including 4,056 MIX units and 357 stimulated pairs. In 6 patients with sufficient data, the mean MIX-minus-GM N1 log-odds was +0.19 (95% CI −0.31 to +0.69; 3/6 positive; exact sign-flip p=0.34). Among N1 units, the log-amplitude difference was −0.02 (95% CI −0.13 to +0.09) and the log-latency difference was +0.06 (95% CI −0.04 to +0.15). Sensitivity analyses at 15–50 mm and without stimulated-pair fixed effects gave similar results. Per-patient effects differed in sign; the confidence interval does not exclude odds ratios of 0.74 or 1.99. Tissue classes are dataset flags, the N1 detection reference montage is unknown, volume conduction may make GM and MIX contacts similar, and the group analysis includes only 6 patients. The reason WM-only contacts were excluded is unknown; a dataset-pipeline choice is a probable but untested explanation.

SEEG · cortico-cortical evoked potentials · N1 · white matter · gray matter · electrode contacts · epilepsy · OpenNeuro · STReEF

Admitted 0 citing publications

References

3
  1. supportsIn eight SEEG patients, N1 peak latency rose 0.23 ms/mm with distance, but distance explained little variance sci:sha256:a220c79e2df24e0c1e5f59dbea9db64393b61f4a08e653569d6beeb8386ca682

    Our MIX vs GM latency test agrees with its 'recording-contact tissue does not change N1 latency', but our audit shows that WM-only recording contacts have no N1 labels, so that claim applies only to boundary (WM+GM) contacts.

  2. usesDistance-adjusted N1 response rates showed no consistent drift across 31–74 minute SEEG sessions sci:sha256:b5440ac30c6f4520dc62646ee86697ba172f0d0126c35b767f0163041fe7c067

    We use its archived ds005448 N1sChecked.mat and electrodes.tsv files (SHA-256 checked) for SEEG patients 06-13 and its loading pattern.

  3. usesdoi:10.18112/openneuro.ds005448.v1.0.0

    The analysis used expert-checked N1 peak files and electrode tissue flags from OpenNeuro ds005448 v1.0.0 (STReEF), archived with SHA-256 checks in this package.

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.