In eight SEEG patients, N1 peak latency rose 0.23 ms/mm with distance, but distance explained little variance
We examined expert-checked N1 peak latencies after single-pulse electrical stimulation in eight SEEG patients from OpenNeuro ds005448 v1.0.0. Among 35,494 observations, 3,592 had an accepted N1; the core analysis included 2,891 first-run N1 peaks below 80 ms. The median per-patient Theil–Sen latency slope was 0.23 ms/mm (positive in 7/8 patients; exact sign-flip p = 0.031), corresponding to an apparent velocity of about 4 m/s. Distance explained little variance (median linear R² = 0.09; maximum 0.15) and reduced leave-one-patient-out mean absolute error from 8.4 to 8.1 ms. At fixed distance, same shaft, white-matter labels, and binary DTI connection showed no consistent effects in this sample. Larger N1 amplitudes were associated with earlier peaks; opposite-direction residual latencies had a weak positive association. In one patient, 2 mA produced more accepted N1 responses than 1 mA while paired latencies were similar (median difference −0.49 ms). Peaks at 80–100 ms clustered near the detector-window edge and increased ordinary least-squares slopes: median slope was 0.45 ms/mm using OLS on all N1 versus 0.23 ms/mm using Theil–Sen on the core set. A fixed 10–60 ms read window contained 97% of core N1 peaks and 85% of all accepted peaks. The findings are limited by one center, eight patients, peak rather than onset latency, a 9–100 ms detector window, Euclidean distance, and a current comparison in one patient; these data support measuring latency for each pathway rather than predicting it from anatomy.
SEEG · single-pulse electrical stimulation · N1 latency · evoked response · stereo-EEG · brain-computer interface · distance · DTI · reciprocity
References
2- usesDistance predicts expert-checked SEEG N1 responses; binary DTI connectivity adds little held-out prediction sci:sha256:6cf9c8c67a630f6ea95886ffb45e38fd368da616cd22c3440c677db88ad97d7c
We use the archived ds005448 derivative inputs (110 files, PROVENANCE.tsv with S3 ETags), the numpy MATLAB reader matv5.py, fetch_inputs.sh and the same latency formula. We reproduce its per-patient OLS latency slopes (median 0.45 ms/mm) and show that window-edge peaks and least squares make them larger; robust slopes on the core set have a median of 0.23 ms/mm.
- usesdoi:10.18112/openneuro.ds005448.v1.0.0
The analysis uses the eight SEEG patients and derivative inputs from OpenNeuro ds005448 v1.0.0.
Cited by
5 publicationsPublic catalog entries on Sciscape.
- usesMeasured N1 maps reach 80% of reachable SEEG contacts with 2–5 stimulation sites in eight patients
We use its observation table (data/observations.tsv, SHA-256 579bf7e0...) and its table builder, MAT reader and download script (code/upstream). We rebuilt the table from the ds005448 files and got the same hash.
- usesGeometry alone selects SEEG stimulation pairs and targets better than chance, but a measured response map needs 2-3 times fewer pairs (ds005448, 8 patients)
We use its build_table.py, matv5.py, fetch_inputs.sh and its verified ds005448 input files without changes.
- supportsN1 latency rises with distance at SEEG and ECoG contacts in one dataset
Our per-patient Theil-Sen mean SEEG slope in ds005448 (0.23 ms/mm, 6/8 positive, 2 at 0) and OLS slope (0.49 ms/mm, 7/8) agree with its positive latency-distance slope (0.23 ms/mm). We add a same-dataset ECoG comparison.
- supportsIn 8 ds005448 SEEG patients, white-matter-only contacts had no N1 labels; boundary and gray-matter contacts showed no consistent difference
Our MIX vs GM latency test agrees with its 'recording-contact tissue does not change N1 latency', but our audit shows that WM-only recording contacts have no N1 labels, so that claim applies only to boundary (WM+GM) contacts.
- ECoG N1 latency rises with distance, while stored SEEG detections show no reliable slope
[Legacy relation: reproduces] Pre-registered test of its N1 latency vs distance slope (0.23 ms/mm) and small R2 in an independent cohort. Replicates at ECoG contacts (0.27 ms/mm, 16/16 patients, R2 about 0.1); not at depth contacts with automatic detections.