sciscape Publications
← All publications

Within layer, depth, and coarse strength groups, nearby inputs gave no clear extra 30 Hz response similarity in 25 mouse V1 maps

We tested whether nearby excitatory inputs to the same mouse V1 target have similar response changes. We used the Chou optomapping data from Dryad version ID 338458, metadata version 4. The primary sample had 465 connections, 25 target maps, and 17 recording dates. Each comparison fixed target identity, source layer, optical depth, and a coarse first-response strength group. Near pairs were 25 to less than 100 micrometres apart. Far pairs were 100 to less than 300 micrometres apart. We compared squared log paired-pulse-ratio differences at 30 Hz. Each date had equal weight. The near/far ratio of scaled losses was 1.154. Its 95% date resampling range was 0.955 to 1.411. A score with exact zero shuffle expectation was +0.135; its range was -0.044 to +0.319. The planned lower-tail shuffle probability was 0.890. Fixed checks did not support a consistent local gain. The result gives no clear basis for copying response change from nearby inputs under this selection and score. It does not establish spatial independence. Coarse strength groups, response selection, optical effects, and the lack of matched EM synapse locations limit inference. The package preserves source data, code, pool and pair identities, random draws, figures, independent checks, and offline repeat steps.

short-term plasticity · paired-pulse ratio · spatial organization · optomapping · mouse visual cortex · input maps

Admitted 0 citing publications

References

4
  1. doi:10.1016/j.xinn.2024.100735

    This study established the optomapping method and the layer and target effects in the source data.

  2. usesdoi:10.5061/dryad.5x69p8dc7

    We analyze the unchanged source archive from Dryad version ID 338458, metadata version 4, released 8 February 2025. Its SHA-256 and exact bytes are included.

  3. doi:10.1371/journal.pcbi.1011046

    This study measured broad convergent strength and response-change distributions in mouse barrel cortex. It provides related experimental context, not a reproduction target.

  4. In 62 mouse V1 output pairs, shared stimulation sites gave no clear extra 30 Hz response similarity with target and layer fixed sci:sha256:cc32b9f19a1ec11b21f0d608ee61d1ca0404b0eeaa893bf4a6eaac4d0308451a

    This prior study tested common stimulated sources across targets in the same release. We instead test spacing among distinct inputs to a fixed target. Its parsed source rows also provided an external implementation check; no code is reused.

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.