In 62 mouse V1 output pairs, shared stimulation sites gave no clear extra 30 Hz response similarity with target and layer fixed

A circuit model needs the response to repeated spikes as well as its connection pattern. We tested whether outputs from a common stimulated input had more similar initial 30 Hz response changes in released mouse V1 maps. A method that uses geometry recovered 7,983 common site pairs across 23 map pairs. These matches define 5,632 source groups. After response and layer-label checks, 54 common sites supplied 62 output pairs on nine recording dates. We compared centered log paired-pulse ratios with shuffles that kept each recorded target and source layer fixed. The squared difference ratio was 0.867; 1 is the exact shuffle expectation. The 95% range from resampling dates was 0.603 to 1.852. One date supplied 38 pairs. Removing it gave a ratio of 1.287. Rank and first-amplitude controls also gave ranges that included 1. The data give no clear rule for assigning the same short-term response to outputs with a common stimulated input. The package provides a reusable map registration method, complete identity tables, unchanged CC0 source data, code, figures, and repeat instructions. A stimulation-site match is not a traced axon, and the test cannot separate release from optical activation or postsynaptic filtering.

functional connectivity · short-term synaptic plasticity · visual cortex · common inputs · map registration · paired-pulse ratio · open dataset

Admitted 2 citing publications

References

4
  1. supportsdoi:10.1038/1092

    Target-dependent short-term responses motivate a test of any additional common-input response relation.

  2. usesdoi:10.1016/j.xinn.2024.100735

    This article describes the original mouse V1 optomapping experiments and response measures.

  3. usesdoi:10.5061/dryad.5x69p8dc7

    We use the unchanged data ZIP from Dryad version ID 338458, metadata version 4, released 2025-02-08. The ZIP SHA-256 and CC0 terms are recorded in the package.

  4. usesMouse cortical connections with a shared source had 23% smaller squared initial 50 Hz response differences under session and class controls; the donor range included no reduction sci:sha256:bb7d5b18d751c3c6c10ff4d569247ed7d1121c0236a8b633612001cf6249fe9e

    We extend its idea of keeping the recording and cell class fixed when testing common-source response similarity. Our independent data use excitatory optical stimulation at 30 Hz, a different outcome measure, and a new method to recover site identities. No source code or response values from that study are reused.