A five-pulse geometric median did not show lower normalized SEEG forecast error than noise scaling under one simulated fivefold gain fault in eight patient sessions
We tested five-pulse response calibration with public SEEG data from OpenNeuro ds004696 version 1.0.1. Eight patient sessions included 86 stimulation sites and 886 stimulation-to-recording pairs. One early pulse waveform had a simulated +5 voltage gain. Each forecast was tested on five separate later pulses. The primary loss normalized each pair by its unchanged calibration energy and gave each patient equal weight. The geometric median had a mean patient error increase of 2.52% relative to a noise-scaled mean. The 95% patient bootstrap interval was -1.51% to 6.62%; the exact two-sided sign-flip p value was 0.3047. The median reduced error by 46.15% relative to the ordinary mean under the same fault. With raw voltage loss, it reduced error by 18.42% relative to noise scaling. The loss definition changed the comparison. An added proof shows a finite amplitude bound for noise scaling when one pulse is replaced by any waveform. The package has exact trial products, all fits and losses, five figures, code, source hashes, and rebuild instructions. A source rebuild for one patient and a full analysis rerun matched the archived inputs and results. This study did not test an online BCI or a new session.
SEEG · signal processing · geometric median · brain-computer interface · forecast error · robust estimation · electrical stimulation
References
4- usesFive-pulse noise scaling reduced later single-pulse error for 20–500 ms centered bipolar SEEG in eight patient sessions sci:sha256:fbc06ab469d48eac7a6f54dd97cd24ccd9c7c5ca4b0db4d64340536b3e81428a
We reused the exact trial products, eligibility rules, and noise-scaled mean rule. We tested a geometric median under specified digital gain faults on the same eight sessions.
- usesA five-pulse check selected more repeatable bipolar SEEG pairs within eight epilepsy patient sessions sci:sha256:b5b7963746f5c6d2a2a8f7844ec590732a4eb152bc7a70979b3bc95c3e27820f
We reused the pinned source retrieval and extraction code and the exact Gram-matrix data definition. A fresh source rebuild for one patient matched its data products.
- usesdoi:10.18112/openneuro.ds004696.v1.0.1
Source dataset, exact version 1.0.1, used for the eight patient sessions.
- doi:10.1523/JNEUROSCI.2201-22.2023
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesA scaled pulse triplet kept five-pulse SEEG forecast size bounded under two replacements and increased error in eight unchanged sessions
Its geometric-median comparison supplied an established robust reference for unchanged and artificial-fault calibration.
- usesA scaled pulse triplet kept five-pulse SEEG forecast size bounded under two replacements and increased error in eight unchanged sessions
Its geometric-median comparison supplied an established robust reference for unchanged and artificial-fault calibration.