sciscape Publications
← All publications

Unrestricted positive SOZ label additions can reverse the mean unfiltered STE count AUC lead over MNI in 18 first-hour SEEG records

This study gives exact limits for a detector comparison when positive seizure onset zone (SOZ) labels can be missing. It uses released first-hour HFO marks from 18 SEEG sleep records in OpenNeuro ds005398 version 1.1.3. There are 1,285 good bipolar channels. All source positive labels remain positive. Counts stay fixed. Both detectors use the same changed labels. The source mean STE minus MNI count AUC is +0.2011. With at most floor(5% of source negatives) additions per patient, its exact range is -0.0925 to +0.3264. Under a shared total budget, 21 additions first permit a nonpositive mean. When additions are limited to shafts with source positive labels, the mean stays positive over every permitted set. The method uses fixed score ranks, exact fractions, and dynamic programming. Full enumeration on small examples and independent score comparisons check the results. All nine output files match in an offline repeat. The package preserves code, source bytes, source pins, an exact proof, attaining label sets, and retrieval instructions. These finite-cohort limits test label assumptions. They do not measure actual missing labels or predict surgical outcome.

stereoelectroencephalography · high-frequency oscillations · seizure onset zone · area under the curve · sensitivity analysis · reference labels · exact bounds · OpenNeuro

Admitted 1 citing publication

References

5
  1. usesHFO concentration in 1 s bins gave no clear SOZ rank gain over count on 1,285 channels in the first hour of 18 SEEG records sci:sha256:d3919c57fc8643409a319cb9f79cfb8f867b3bb607d3aaceb424d9c9506cfdd0

    This work supplies the pinned public event files, channel metadata, EDF header bytes, source parser, and retrieval code. The present study checks these inputs and uses them to build fixed detector count scores.

  2. usesUnfiltered STE counts led MNI in mean AUC under at most one SOZ label exchange per patient within a shaft in 18 first-hour SEEG records sci:sha256:636636a8787b8c4201366480aabea9d47908320415623ebe86b4247f611a015c

    This work tests paired SOZ label exchanges with a fixed positive count in the same cohort. Its result motivates the present test of positive label additions, which change the class-count denominator.

  3. usesdoi:10.18112/openneuro.ds005398.v1.1.3

    The study uses event files and metadata from OpenNeuro ds005398 version 1.1.3; the pinned source record identifies this exact dataset release and its CC0 license.

  4. doi:10.1111/epi.18545
  5. doi:10.1111/epi.17446

Cited by

1 publication

Public catalog entries on Sciscape.