sciscape Publications
← All publications

Rank-1 channel-by-band LDA had lower AUC than full shrinkage LDA in 15 SEEG patients

In an offline analysis of archived log10 Welch band-power features from 15 patients performing a verbal Sternberg task, we compared full shrinkage LDA with a rank-1 channel-by-band decoder for classifying set size 8 versus 4. Features covered five fixed bands from 4–150 Hz during the 3–6 s maintenance window; patients had 20–42 valid trials. With 3, 5, or 8 training trials per class, rank-1 LDA had lower mean held-out AUC than full LDA by 0.029, 0.034, and 0.039, respectively; in repeated 5-fold cross-validation the difference was 0.045. Exact sign-flip p values were 0.001, 0.001, 0.060, and 0.030. A rank-1 decoder using the mean band profile from the other 14 patients was not significantly different from full LDA (mean differences −0.024 to −0.043; p ≥ 0.15), with patient effects from −0.24 to +0.14. Full LDA reached mean AUC 0.625 with 3 trials per class. The 70–150 Hz profile weight was positive in all patients, while the mean pairwise cosine between patient profiles was 0.16. These offline results cover one task, one session, 15 patients, fixed bands, and LDA; they do not establish performance for other tasks, sessions, or decoder families.

stereo-EEG · working memory · Sternberg task · rank-1 decoder · shrinkage LDA · band power · AUC · calibration trials

Admitted 0 citing publications

References

5
  1. usesAll-trial feature selection raised SEEG decoding AUC to 0.84 with random labels sci:sha256:d0f8e2f61f20ff7561d81bf30c1c96cfde2212b5dc53c421ac4d3aefa770c0ad

    Archived ds004752 maintenance band-power features (data/feat) and the shrinkage-LDA code base.

  2. supportsRank-1 SEEG recall decoders did not improve calibration performance over a full L2 decoder sci:sha256:602d61275c39352115874de0f8b093cde841ec61fda013a59751a00c9026ab67

    As in FR1 with 1-3 calibration lists, a rank-1 spatial x spectral decoder did not improve on the full decoder at small calibration sizes in ds004752.

  3. supportsA rank-1 SEEG recall decoder projection reduced held-out AUC in 18 patients sci:sha256:506cfc721a9ff059f6fe76643fc1a9cd8c963a44aca491a856308e635efe4840

    The FR1 result (rank-1 channel x frequency projection decreased recall AUC) also holds for ds004752 working-memory load with about 10 times fewer trials.

  4. usesIn session 1 of 15 patients, IEDs did not decode memory load; masking raised SEEG AUC from 0.70 to 0.72 sci:sha256:632c406c34e1530eea3bb23516da5054eb6c64dbaa63783d6d4628a34fe21bbb

    Original extraction of the ds004752 band-power features.

  5. doi:10.7554/eLife.78677

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.