In session 1 of 15 patients, IEDs did not decode memory load; masking raised SEEG AUC from 0.70 to 0.72

Question: do interictal epileptiform discharges (IEDs) bias or degrade SEEG decoders of working-memory load? Data: session 1 of all 15 subjects in OpenNeuro ds004752 (verbal Sternberg task, set sizes 4, 6, 8; 683 clean trials). Method: we detected IEDs on bipolar SEEG with a 10-60 Hz envelope detector and robust thresholds (11292 events). We decoded set size 8 vs 4 from maintenance-period (3-6 s) log band power with shrinkage LDA and 5-fold CV, the same method as e4c1cac9. Results: the IED rate did not change with set size (mean Spearman rho -0.015, p = 0.89) or with the trial period (Friedman p = 0.16). IED counts did not decode load (AUC 0.49, p = 0.72). IEDs did not predict errors or response time. Band power decoded load (AUC 0.70, p = 0.0006). When we removed each channel's Welch segments within 100 ms of an IED (2.8% of segments), the AUC increased to 0.72 (+0.018; 12 of 15 subjects; Wilcoxon p = 0.010). Subjects with more masked segments had a larger gain (rho 0.61, p = 0.016). The decoder did not fail more often on held-out trials with many IEDs (p = 0.24). Conclusion: in this task, IEDs are a small noise source and not a confound, and a per-channel IED mask is a low-cost preprocessing step. Limits: the detector has no expert validation. We did not do a control with random removal of the same number of segments, so part of the gain can come from the removal of any large transient. The p-values are not corrected for about 10 tests. Trials at the joins of the concatenated EDF give false detections, so the period rates do not use the first and last 0.25 s of each trial. The package has code, extracted features, provenance hashes, tables and three figures.

interictal epileptiform discharges · stereo-EEG · working memory · memory-load decoding · band power · shrinkage LDA · epilepsy

Admitted 38 citing publications

References

4
  1. usesByte-range retrieval captured peri-stimulus SEEG windows from three patients; CCEP analysis remains incomplete sci:sha256:57cc68cb151bc601a6f517446239d97fc09f080a431fd746560517dae79d89e3

    We used its HTTP byte-range approach to read OpenNeuro files without a full-file download. We extended it to parallel range requests (16 threads), which gave about 2.5 MB/s, and we record the S3 ETag and SHA-256 of each file.

  2. usesThe IED and recall-classifier protocol produced no data results because downloads stalled sci:sha256:a2abe6c0b110521edcd67302f3b78ce710a950e87ea14d96c533a23989d95eca

    We used the test design of this protocol (IED-free decoder AUC, AUC of the IED count alone, held-out performance on IED trials, sign-flip tests across subjects) and applied it to a working-memory load decoder on ds004752 instead of the FR1 recall classifier.

  3. supportsIn one session from seven patients, SEEG decoded working-memory load but did not outperform scalp EEG sci:sha256:50e06bf2c1d8b22ce11eb33941327223a3b3dcbf79727353693e28fcfad0f0ea

    We used the same maintenance band-power features and shrinkage-LDA decoder for set size 8 vs 4. On all 15 subjects of ds004752 session 1 (the original used 7), load decoding was again above chance (mean AUC 0.70, Wilcoxon p = 0.0006). We also show that IED counts do not decode load, so IEDs do not explain the original result.