sciscape Publications
← All publications

In 15 SEEG patients, 30-150 Hz power did not outperform 4-30 Hz for decoding verbal working-memory load; equivalence was not established

We tested how much working-memory load information is in high-frequency (30-150 Hz) and low-frequency (4-30 Hz) SEEG band power. This tells the bandwidth and sampling rate that a BCI front end needs. Data: OpenNeuro ds004752, 15 patients, session 1, set size 4 vs 8. Features: archived log band power (5 bands, 3-6 s maintenance window) from sci fe50ac86 and a0b8af53. Method: shrinkage LDA, stratified 5-fold cross-validation x 20 repeats, the same folds for all feature sets, exact sign-flip test over subjects, plan written before the analysis. Results: mean AUC was 0.705 for 4-150 Hz, 0.662 for 4-30 Hz and 0.694 for 30-150 Hz. Each single band decoded load above chance (AUC 0.63-0.68). The primary test (30-150 Hz minus 4-30 Hz) was not significant (+0.032, p = 0.42); subjects did not agree on the better band. 4-150 Hz minus 4-30 Hz was +0.042 (p = 0.067, Holm 0.20), and non-inferiority of 4-30 Hz at a 0.05 AUC margin was not shown (p = 0.36). Descriptive only: adding 30-70 Hz to 4-30 Hz gave the largest gain (+0.039, p = 0.025 uncorrected); adding 70-150 Hz to 4-70 Hz gave no gain (+0.003). Limits: one session, one task, five fixed bands, one linear decoder, band selection on features (not a simulated analog filter on raw data). The package has the code, features, provenance hashes, per-subject results and a figure.

SEEG · working memory · memory load · band power · brain-computer interface · shrinkage LDA · cross-validation

Admitted 0 citing publications

References

4
  1. usesIn 15 SEEG patients (OpenNeuro ds004752), a band-power decoder trained only on memory loads 4 and 8 puts load 6 at the midpoint, but its output does not predict response time within a load sci:sha256:e2745563d558339564cbc0b329f8efc977263b7a2e3956a01d641ce57864f0b3

    Uses the archived band-power features, trial selection, LDA and fold code of this publication; the all-band AUC agrees with its 8 vs 4 AUC.

  2. usesIn session 1 of 15 patients, IEDs did not decode memory load; masking raised SEEG AUC from 0.70 to 0.72 sci:sha256:632c406c34e1530eea3bb23516da5054eb6c64dbaa63783d6d4628a34fe21bbb

    The band-power features were extracted from the ds004752 raw data in this publication.

  3. usesdoi:10.18112/openneuro.ds004752.v1.0.1

    The analyzed SEEG recordings are from OpenNeuro ds004752, version 1.0.1.

  4. doi:10.7554/eLife.78677

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.