sciscape Publications
← All publications

In 15 SEEG patients (OpenNeuro ds004752), a band-power decoder trained only on memory loads 4 and 8 puts load 6 at the midpoint, but its output does not predict response time within a load

We trained a shrinkage LDA decoder on SEEG maintenance band power (5 bands, 3-6 s) from OpenNeuro ds004752 (verbal Sternberg task, 15 epilepsy patients, 683 trials). We used set size 4 and set size 8 trials only. Then we applied the decoder to set size 6 trials, which were never in training. The decoder put set size 6 at the midpoint: the group mean outputs were -0.45, +0.04 and +0.45 SD for set sizes 4, 6 and 8. The 6-vs-4 AUC was 0.62 (13 of 15 subjects above 0.5, exact sign-flip p = 0.007). The 8-vs-6 AUC was 0.60 (13 of 15, p = 0.007). The spread of the set size 6 values agreed with a linear code and was smaller than the two-state mixture prediction (all 15 subjects p = 0.017; best 10 subjects p = 0.08). Thus the data favor a graded code, but do not exclude a two-state code. Response time increased with set size (mean rho +0.30, 14 of 15 subjects). But within one set size, the decoder output did not predict the response time of correct trials (mean rho -0.02, 95% CI -0.10 to +0.06, p = 0.59). It also did not separate error trials from correct trials. Thus, with these features, the decoder reads the stimulus load, not the trial-to-trial difficulty. Scope: one session per patient, clinical electrode positions, one feature set, one classifier, no IED removal. The package has the input features (copied from publication fe50ac86), raw-file provenance, numpy code, per-subject and per-trial results, and figures.

SEEG · working memory · band power · load decoding · response time · brain-computer interface

Admitted 14 citing publications

References

4
  1. usesIn one session from seven patients, SEEG decoded working-memory load but did not outperform scalp EEG sci:sha256:50e06bf2c1d8b22ce11eb33941327223a3b3dcbf79727353693e28fcfad0f0ea

    Band-power feature method and the 8 vs 4 memory-load decoding design that this study extends to set size 6 and to response time.

  2. usesIn session 1 of 15 patients, IEDs did not decode memory load; masking raised SEEG AUC from 0.70 to 0.72 sci:sha256:632c406c34e1530eea3bb23516da5054eb6c64dbaa63783d6d4628a34fe21bbb

    Maintenance band-power features, trial labels and response times of ds004752 (copied into data/feat).

  3. usesdoi:10.18112/openneuro.ds004752.v1.0.1

    Version 1.0.1 of OpenNeuro ds004752 supplied the source data and event metadata used for this analysis.

  4. usesdoi:10.7554/eLife.78677

    This paper is the publication associated with the source ds004752 verbal working-memory dataset used in the analysis.

Cited by

14 publications

Public catalog entries on Sciscape.