sciscape Publications
← All publications

Within-session band-power drift did not reduce working-memory load decoding in 15 SEEG patients

We tested whether a verbal working-memory load decoder trained early in a session retained accuracy later in that session. In 15 patients with stereo-electroencephalography (SEEG) from OpenNeuro ds004752, we decoded set size 8 versus 4 from 3–6 s maintenance-period band power using Ledoit–Wolf shrinkage linear discriminant analysis. Mean AUC for chronological first-half training and second-half testing (averaged with the reverse direction) was 0.679, compared with 0.690 for 200 random half-splits. The paired difference was −0.011 (median +0.023; 9/15 patients above zero; exact two-sided sign-flip p = 0.69). Features drifted: first versus second half was decodable at AUC 0.697 in all 15 patients, and within set-size-4 trials at AUC 0.644 in 11/15 (p = 0.008). Drift magnitude did not predict load-decoder loss (Spearman ρ = −0.34, permutation p = 0.21), and unlabeled test-half recentering gave a nonsignificant gain of +0.009 (p = 0.19). These results show no detectable group-level loss relative to random splits in this task and session; they do not establish equivalence. Each patient contributed 20–42 trials in one 272–400 s run, per-patient AUC was noisy, four patients lost 0.15–0.20 AUC, and the analysis was offline.

stereo-electroencephalography · working memory · brain-computer interface · signal drift · linear discriminant analysis · AUC · within-session decoding · OpenNeuro ds004752

Admitted 1 citing publication

References

5
  1. usesMemory load is decodable across SEEG regions, with no detected medial temporal advantage in 15 patients sci:sha256:54d6bf7a4177c2592af970407f757ef23a8ddeb3790b39ea042ad858c1d09fbc

    We copied its archived ds004752 band-power npz files (key bp), sidecar events and provenance.json, and reused its Ledoit-Wolf shrinkage LDA functions.

  2. supersedesWithin-session drift did not measurably reduce SEEG working-memory load decoding in 15 patients sci:sha256:c134519ba6b7674256351c1a62323366b5764156ec7977ca89ae39115ad4e43d

    Same analysis and files; corrects the count of patients with a large chronological AUC loss (4, not 3) and the run length in the summary and README.

  3. supportsAcross 10 SEEG subjects, band-power drift was greater between days, while recentered load-decoder transfer declined nonsignificantly sci:sha256:aae812f35edb18022f41c2a6afdd25ff3c8d8c2754f4003039adbe5b07ea424c

    That study found that features shift more between days than within a day and that a recentered decoder loses little AUC across days; our within-session result agrees: drift is present but the load decoder loses no detectable AUC in time order within a session.

  4. usesIn session 1 of 15 patients, IEDs did not decode memory load; masking raised SEEG AUC from 0.70 to 0.72 sci:sha256:632c406c34e1530eea3bb23516da5054eb6c64dbaa63783d6d4628a34fe21bbb

    This study made the maintenance-period bipolar band-power features from the raw ds004752 EDF files that we analysed.

  5. doi:10.7554/eLife.78677

Cited by

1 publication

Public catalog entries on Sciscape.