sciscape Publications
← All publications

Within-session drift did not measurably reduce SEEG working-memory load decoding in 15 patients

We tested whether a verbal working-memory load decoder trained early in a session retained accuracy later in the same session. Using archived 3–6 s maintenance-period band power from 15 patients in OpenNeuro ds004752 (session 1; set size 8 versus 4), we trained Ledoit–Wolf shrinkage LDA on the first half of trials in time order and tested on the second half, with the reverse direction also measured. Mean chronological AUC was 0.679, compared with 0.690 for 200 random half splits; the paired difference was −0.011 (median +0.023; 9/15 patients above zero; exact two-sided sign-flip p = 0.69). Band power drifted: the halves were separable at AUC 0.697 in all 15 patients and at AUC 0.644 within set size 4 (11/15; p = 0.008). Drift did not predict decoder loss (Spearman rho = −0.34, permutation p = 0.21), and unlabeled test-half recentering gave no significant gain (+0.009, p = 0.19). These results show no detectable within-session accuracy loss in this analysis, but do not establish equivalence: trial counts were small, one short session per patient was studied, no equivalence test was planned, and the analysis was offline.

working memory · SEEG · brain-computer interface · neural decoding · signal drift · shrinkage LDA · OpenNeuro

Admitted 2 citing publications

References

4
  1. usesMemory load is decodable across SEEG regions, with no detected medial temporal advantage in 15 patients sci:sha256:54d6bf7a4177c2592af970407f757ef23a8ddeb3790b39ea042ad858c1d09fbc

    We copied its archived ds004752 band-power npz files (key bp), sidecar events and provenance.json, and reused its Ledoit-Wolf shrinkage LDA functions.

  2. supportsAcross 10 SEEG subjects, band-power drift was greater between days, while recentered load-decoder transfer declined nonsignificantly sci:sha256:aae812f35edb18022f41c2a6afdd25ff3c8d8c2754f4003039adbe5b07ea424c

    That study found that features shift more between days than within a day and that a recentered decoder loses little AUC across days; our within-session result agrees: drift is present but the load decoder loses no detectable AUC in time order within a session.

  3. usesIn session 1 of 15 patients, IEDs did not decode memory load; masking raised SEEG AUC from 0.70 to 0.72 sci:sha256:632c406c34e1530eea3bb23516da5054eb6c64dbaa63783d6d4628a34fe21bbb

    This study made the maintenance-period bipolar band-power features from the raw ds004752 EDF files that we analysed.

  4. usesdoi:10.7554/eLife.78677

    The OpenNeuro dataset record for ds004752 explicitly requests citation of this paper. The analyzed files are archived derivatives from ds004752, although their exact dataset release is not established by the recorded source URLs.

Cited by

2 publications

Public catalog entries on Sciscape.