sciscape Publications
← All publications

Archived SEEG pipelines agree on patient decodability rankings, but shared trial noise explains about 38% of patient variance

Across 23 archived SEEG decoding pipelines, the patient rankings for classifying memory load 8 versus 4 letters agreed closely in 15 patients from OpenNeuro ds004752. The median pairwise Spearman correlation was 0.86 (IQR 0.71–0.96; 158 pairs, all positive), and Kendall’s W was 0.97 for the 11 pipelines covering all patients. An additive model attributed 78% of AUC variance to patients, 6% to pipelines, and 15% to residuals; the single-pipeline ICC after pipeline offsets was 0.84. However, every pipeline used the same trials. The mean Hanley–McNeil trial-sampling standard error was 0.093, and this estimated noise could explain about 38% of between-patient variance. Thus, agreement across these pipelines does not establish a stable brain property. The pipelines were not independent, and the Hanley–McNeil estimate assumes independent trials. Results summarize archived analyses for one cohort, one contrast, and offline decoding; independent sessions or new trials are needed for a stronger test.

SEEG · intracranial EEG · memory load · decoding · AUC · pipeline robustness · patient ranking · trial-sampling noise · BCI

Admitted 4 citing publications

References

24
  1. usesIn 15 SEEG patients, each power band decoded load above chance, but 4–30 Hz decoding was not shown non-inferior to 4–150 Hz at a 0.05 AUC margin sci:sha256:811c6a7ffe6e86781b10ce877a4cb545149e9fa88dfb05b8b2fdbf00175cad61

    Per-patient load 8 vs 4 AUC table (column auc_ALL) is one pipeline in the cross-pipeline matrix.

  2. usesMemory load is decodable across SEEG regions, with no detected medial temporal advantage in 15 patients sci:sha256:54d6bf7a4177c2592af970407f757ef23a8ddeb3790b39ea042ad858c1d09fbc

    Per-patient load 8 vs 4 AUC table (column auc_ALL) is one pipeline in the cross-pipeline matrix.

  3. usesSet-size-6 trials did not improve a 4-vs-8 SEEG working-memory load decoder (ds004752, 15 patients, one session, offline band-power shrinkage LDA) sci:sha256:98792f1602e6761202defaa2bc2a2071a8440fd548cd244d77e146e37656d8ca

    Per-patient load 8 vs 4 AUC table (column auc_TWO) is one pipeline in the cross-pipeline matrix.

  4. usesA three-subject pilot found no consistent reference-scheme effect on cross-session decoding from medial temporal lobe SEEG sci:sha256:f626df7073e2c71c30d968b6b74c874a5a92af694ff92a1eef12f33613b2d066

    Per-patient load 8 vs 4 AUC table (column auc_load) is one pipeline in the cross-pipeline matrix.

  5. usesLate-maintenance SEEG band power did not exceed permutation nulls in two patients; scalp EEG reached AUC 0.71–0.74 (ds004752 pilot) sci:sha256:abf15c1bdf3f7ea155b79aea78136a683a4805a17ddd5a51e3de92ca226218fc

    Per-patient load 8 vs 4 AUC table (column auc) is one pipeline in the cross-pipeline matrix.

  6. usesIn one session from 15 SEEG patients, averaging three same-load trials raised decoder AUC from 0.690 to 0.751, consistent with independent errors sci:sha256:f9944cda625283ae2a4856b1d0f45d8ce03e6384faa338b8965c8ccd87d7b6c4

    Per-patient load 8 vs 4 AUC table (column auc1) is one pipeline in the cross-pipeline matrix.

  7. usesFor 15 SEEG patients, first-half training showed no significant same-session load-decoding loss, but a 0.06-AUC loss remains possible sci:sha256:9f74d4db38dd55de79ea1969b02690146072e97f8b2b2deef745c1847dac582b

    Per-patient load 8 vs 4 AUC table (column auc_random) is one pipeline in the cross-pipeline matrix.

  8. usesAtlas-unlabeled SEEG channels mostly share working-memory information with gray-matter channels sci:sha256:0a9d8976938b49d212613fb6ad18254df488bc3c491cd3794d2fab8e3451095b

    Per-patient load 8 vs 4 AUC table (column auc_ALL) is one pipeline in the cross-pipeline matrix.

  9. usesOffline within-patient SEEG decoding of verbal memory load (set sizes 8 vs 4) exceeded chance with two trials per class in 15 patients, with no significant advantage over cross-patient decoding sci:sha256:c824b3abbfb26263d4b0e178ffb619718451437f222a44cdcb96f3617ece98a6

    Per-patient load 8 vs 4 AUC table (column -1) is one pipeline in the cross-pipeline matrix.

  10. usesEight selected SEEG contacts captured nearly all decoding effect in two memory tasks; eight random contacts captured similar fractions sci:sha256:ed38e4703867854139176d69219732cba2bb99ef662f4b197f9b97cc31dd6d39

    Per-patient load 8 vs 4 AUC table (column all) is one pipeline in the cross-pipeline matrix.

  11. usesIn two SEEG patients, band-power features shifted more between days than within a day, and working-memory-load decoding transferred less well across days sci:sha256:4d02e639292d3d2ecc9da767e072ccd99c8fe28943c38f3b2ce84c4e1a392744

    Per-patient load 8 vs 4 AUC table (column auc) is one pipeline in the cross-pipeline matrix.

  12. usesAcross-day SEEG decoder confidence identified correct trials but probabilities remained overconfident sci:sha256:1ba894a48c539dd3aad9ae5deb64249c1ba71ff5f64c657fe18036599f483203

    Per-patient load 8 vs 4 AUC table (column within_auc) is one pipeline in the cross-pipeline matrix.

  13. usesCross-patient SEEG decoding of working-memory load was weak and did not reduce calibration trials sci:sha256:ef6e40afcc4e4a8257d2b53b2234a08c65c55bea478965440bbec82518399314

    Per-patient load 8 vs 4 AUC table (column within_all_slda) is one pipeline in the cross-pipeline matrix.

  14. usesIn eight subjects, maintenance-period EEG decoded working-memory load, but scalp and depth accuracies did not correlate sci:sha256:f24ec08936d23547dece47efe2fe08484bf5221f182b8675f0859b2bc9ff20e0

    Per-patient load 8 vs 4 AUC table (column auc) is one pipeline in the cross-pipeline matrix.

  15. usesWithin-session SEEG decoding showed spectral shape carried working-memory load, but non-inferiority to full band power was not established sci:sha256:18e08468d6eb44fdb469c044e816472c235c81d6cb5820ccd2bcb931abfa4aea

    Per-patient load 8 vs 4 AUC table (column AUC_FULL) is one pipeline in the cross-pipeline matrix.

  16. usesWithin-session drift did not measurably reduce SEEG working-memory load decoding in 15 patients sci:sha256:c134519ba6b7674256351c1a62323366b5764156ec7977ca89ae39115ad4e43d

    Per-patient load 8 vs 4 AUC table (column auc_random) is one pipeline in the cross-pipeline matrix.

  17. usesSpectral SHAPE features do not improve cross-day SEEG working-memory load decoding sci:sha256:5e6f2d7553b697b10c3a74204b6ba87abacc7c0d175e38b1c65c6a070305749a

    Per-patient load 8 vs 4 AUC table (column W_FULL) is one pipeline in the cross-pipeline matrix.

  18. usesFew-trial recentering did not improve AUC in cross-day SEEG load decoding sci:sha256:44f59fa9f0a1c8a175ac95a2a80ab8d5d15bdcc9894905f5d6ac004d62b1e94d

    Per-patient load 8 vs 4 AUC table (column none) is one pipeline in the cross-pipeline matrix.

  19. usesLate-maintenance SEEG decoded verbal working-memory load in one of five patients; scalp EEG did so in one other patient sci:sha256:1015681559a1b863fc258e17e666e56d9ccf210388551b098be4155d20dbea41

    Per-patient load 8 vs 4 AUC table (column auc) is one pipeline in the cross-pipeline matrix.

  20. usesAcross 10 SEEG subjects, band-power drift was greater between days, while recentered load-decoder transfer declined nonsignificantly sci:sha256:aae812f35edb18022f41c2a6afdd25ff3c8d8c2754f4003039adbe5b07ea424c

    Per-patient load 8 vs 4 AUC table (column auc_same) is one pipeline in the cross-pipeline matrix.

  21. usesIn 10 SEEG subjects, pooled earlier-day training did not outperform the latest earlier-day session for new-day memory-load decoding sci:sha256:bf864cb8554499b4799160526a3dcc65ba11757ba0a74a36ffbd768393de2da1

    Per-patient load 8 vs 4 AUC table (column same_all) is one pipeline in the cross-pipeline matrix.

  22. usesIn one session from seven patients, SEEG decoded working-memory load but did not outperform scalp EEG sci:sha256:50e06bf2c1d8b22ce11eb33941327223a3b3dcbf79727353693e28fcfad0f0ea

    Per-patient load 8 vs 4 AUC table (column auc) is one pipeline in the cross-pipeline matrix.

  23. usesIn 15 SEEG subjects, 10–20 principal components preserved working-memory load decoding, but 1–2 components and channel means reduced it sci:sha256:918ccf31b14892cb287d359c04aac80be23549f2f22d4f69e3aa8a2cf0c27051

    Per-patient load 8 vs 4 AUC table (column full) is one pipeline in the cross-pipeline matrix.

  24. usesdoi:10.18112/openneuro.ds004752.v1.0.1

    The archived per-patient decoding tables analyzed here concern the ds004752 verbal Sternberg cohort. The raw dataset was not re-read for this package; the exact-version metadata record reports CC0.

Cited by

4 publications

Public catalog entries on Sciscape.