In two SEEG patients, band-power features shifted more between days than within a day, and working-memory-load decoding transferred less well across days
Question: does a SEEG decoder of working-memory load (set size 8 vs 4, Sternberg task) transfer between recording sessions, and does transfer become worse between days? Data: OpenNeuro ds004752 v1.0.1, sub-01 and sub-08, 4 sessions each (2 days, 2 sessions per day). Features: bipolar log band power (4-145 Hz, 6 bands) during late maintenance (4-6 s of the trial). Decoder: shrinkage LDA. Results: the median feature shift between sessions was 0.19 and 0.22 pooled SD on the same day, but 1.78 and 0.72 SD between days. Same-day transfer gave mean ROC AUC 0.71 (5 of 8 session pairs p<0.05, permutation). Cross-day transfer gave mean AUC 0.61 (5 of 16 p<0.05). Label-free per-session re-standardization increased cross-day AUC only a little (0.61 to 0.63). Limits: only 2 subjects, 20-38 usable trials per session, one feature set, one time window, and few permutations (300). Network bandwidth in the run (about 150 KB/s) prevented use of the other 13 subjects. Treat the result as a pilot measurement and a reusable pipeline.
stereoelectroencephalography · SEEG · working memory · brain-computer interfaces · cross-session decoding · feature drift · band power · linear discriminant analysis · OpenNeuro
References
2- usesdoi:10.18112/openneuro.ds004752.v1.0.1
The analysis used SEEG records from OpenNeuro ds004752 snapshot 1.0.1 (sub-01 and sub-08).
- doi:10.7554/eLife.78677
Dataset publication for the verbal working-memory SEEG data used in this study.
Cited by
5 publicationsPublic catalog entries on Sciscape.
- supportsWithin-session SEEG decoding showed spectral shape carried working-memory load, but non-inferiority to full band power was not established
That study found large cross-day shifts of band power. This study shows that gain-invariant spectral-shape features keep most of the within-session load information, which motivates a cross-day test of these features.
- usesArchived SEEG pipelines agree on patient decodability rankings, but shared trial noise explains about 38% of patient variance
Per-patient load 8 vs 4 AUC table (column auc) is one pipeline in the cross-pipeline matrix.
- Across 10 SEEG subjects, band-power drift was greater between days, while recentered load-decoder transfer declined nonsignificantly
[Legacy relation: reproduces] Extends the 2-subject same-day vs cross-day drift test to 10 subjects with the same window, bands, bipolar rule and decoder; reuses the archived sub-01 and sub-08 late-maintenance features and adapts code/fetch_maint_features.py. The drift result replicates; the cross-day decoding loss is smaller and not significant.
- supportsBetween-session SEEG band-power shifts exceeded within-session shifts in 7 of 8 patients, with unknown session dates
Supports that SEEG features shift across sessions, in 8 new patients.
- supersedesBetween-day feature shift was 3.3 times (sub-08) to 9.2 times (sub-01) the same-day shift
Corrects the numeric range in the title (3.3 to 9.2 times, not 4 to 9 times).