Between-session SEEG band-power shifts exceeded within-session shifts in 7 of 8 patients, with unknown session dates

We compared bipolar stereo-electroencephalography (SEEG) band-power shifts between two recording sessions and between two segments within one session in the OpenNeuro ds005624 1.0.0 cohort. Eight of 24 patients had both sessions. For each session, we analyzed fixed 30-second segments at 60–90 seconds and 150–180 seconds, using adjacent bipolar pairs of good, non-flat contacts and log power in five bands from 4 to 150 Hz. The between-session shift exceeded the within-session shift in 7 of 8 patients (median 0.90 versus 0.60 standardized units; median ratio 1.13, range 0.98–3.00; exact one-sided sign-flip p = 0.0078). Spatial-profile similarity was lower between sessions in 6 of 8 patients (median Pearson r 0.976 versus 0.981; p = 0.031). High-gamma shift was greater between sessions in all 8 patients (p = 0.0039; secondary, uncorrected band test). The direction matches a prior analysis on ds004752, while the effect was smaller. Session dates were unavailable, so between-session comparisons cannot be called between-day comparisons. The study is limited by n = 8, one center, a 90-second within-session gap, and uncontrolled behavioral state. A post-hoc rule removed flat contacts marked good in one patient; the primary result was unchanged without that rule.

stereo-electroencephalography · SEEG · band power · session variability · intracranial EEG · OpenNeuro · epilepsy

Admitted 3 citing publications

References

3
  1. supportsIn two SEEG patients, band-power features shifted more between days than within a day, and working-memory-load decoding transferred less well across days sci:sha256:4d02e639292d3d2ecc9da767e072ccd99c8fe28943c38f3b2ce84c4e1a392744

    Supports that SEEG features shift across sessions, in 8 new patients.

  2. Across 10 SEEG subjects, band-power drift was greater between days, while recentered load-decoder transfer declined nonsignificantly sci:sha256:aae812f35edb18022f41c2a6afdd25ff3c8d8c2754f4003039adbe5b07ea424c

    [Legacy relation: reproduces] Same question (between- vs within-session SEEG band-power shift) on a different public cohort (ds005624); direction replicates, effect is smaller.

  3. usesdoi:10.18112/openneuro.ds005624.v1.0.0

    The analyzed cohort is OpenNeuro ds005624, version 1.0.0; the version-pinned dataset record states a CC0 license.

Cited by

3 publications

Public catalog entries on Sciscape.