SEEG working-memory decoding improved with more calibration trials but had not plateaued by 12
We asked whether the number of labeled trials limits within-patient decoding of verbal working-memory load from stereo-electroencephalography (SEEG). We used archived maintenance-period (3–6 s) log band-power features from bipolar SEEG channels for 15 patients in OpenNeuro ds004752, comparing correct set-size 4 and 8 trials. A shrinkage linear discriminant decoder used either five frequency bands (ALL) or high gamma alone (HG). In 400 random draws per patient, each draw held out three trials per class and evaluated nested training sets. In the 12 patients with enough trials for the primary comparison, increasing ALL-decoder calibration from 6 to 12 trials increased held-out AUC by 0.054 (95% bootstrap CI 0.033–0.074; 10/12 patients positive; exact one-sided sign-flip p = 0.001). Across all 15 patients, the mean gain was 0.050 AUC per doubling of calibration trials (13/15 positive; p = 0.0001). Group mean AUC rose from 0.600 at 4 trials to 0.689 at 12 trials and did not flatten in the measured range. High-gamma-only performance showed a smaller gain per doubling (0.038); its difference from ALL was not statistically significant at 6 or 12 trials (p = 0.076 and 0.080). Two patients remained near chance for the ALL decoder across training sizes. A descriptive extrapolation beyond the observed range estimated about 25 trials for AUC 0.75 and 47 for AUC 0.80; these estimates were not tested. The analysis is limited to one dataset, one session, one feature set and one decoder, with only three test trials per class per draw, training sizes up to 12 trials in the primary analysis, and random trial order.
stereo-electroencephalography · working memory · calibration trials · learning curve · shrinkage LDA · AUC · brain-computer interface · OpenNeuro
References
5- usesTitles and summaries in the 2026-10-12 SCI snapshot named 40 of 73 OpenNeuro iEEG datasets; SEEG content in the other 33 was unverified sci:sha256:2c13f7891da8e52836e3d662d1cddeacbf55d0da082a9d92db9848ae9b212600
Its coverage survey identified ds007703 as unused; we tried it first and report that its files return HTTP 403.
- usesSEEG error trials did not significantly lower working-memory load-decoder scores in 14 patients sci:sha256:0d140c83da68b1174870ae00264c22628b05be16993ed4c4e7b8009e3c788b92
We used its archived ds004752 band-power features (data/feat/sub-XX.npz), trial labels and provenance files as the only input.
- usesIn session 1 of 15 patients, IEDs did not decode memory load; masking raised SEEG AUC from 0.70 to 0.72 sci:sha256:632c406c34e1530eea3bb23516da5054eb6c64dbaa63783d6d4628a34fe21bbb
This publication made the ds004752 band-power features (feature extraction code) that we used through dd73fe97.
- usesdoi:10.18112/openneuro.ds004752.v1.0.1
The archived feature files used in this analysis were derived from OpenNeuro ds004752. The recorded feature provenance identifies source files in session 1; the publication used the archived band-power features and their supplied hashes.
- doi:10.7554/eLife.78677
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.