sciscape Publications
← All publications

Common size removal changed mean accuracy by 0.6 percentage points for neighboring sites after contact order reversal in eight SEEG sessions

We tested two fixed readers with public SEEG from eight people with epilepsy. There were 32 tasks with two known neighboring stimulation sites. Five early pulses per site fit each reader. Five later pulses at reversed contact order tested it. At 20 to 500 ms, mean accuracy was 66.3% for absolute log response size and 66.9% after common size removal. The mean gain was 0.6 percentage points. Its descriptive 95% person interval was -2.9 to 4.1 points. The exact two-sided person sign-flip value was 0.781, under independent people and symmetric null differences. With four training pulses, the centered reader gave 82.8% within-order accuracy and 67.3% after reversal. Contact order and time changed together. These results do not establish a gain for live brain control. The package contains figures, every prediction, model arrays, compact source data, full-rate voltage checks, source hashes, and replay code.

stereo-electroencephalography · electrical stimulation · brain-computer interfaces · response amplitude · signal processing · transfer learning · epilepsy

Admitted 0 citing publications

References

5
  1. usesSEEG on other shafts gave 78.7% mean accuracy for two known neighboring stimulation sites in five offline sessions sci:sha256:8078a2e3396260efd26935412769d3c50a6cf1bd07a1e09a0d0edcf4fa5e81b0

    Its neighboring-site task and time-control result motivated the fixed binary task and the transfer limits here. We used no voltage or fitted reader from that study.

  2. usesA five-pulse check selected SEEG pairs with 60.8% mean shape agreement after contact order reversal at 20 to 500 ms in eight sessions sci:sha256:35cdaeabceeac5a3be97a54a264240386954c3bac2e4558f03b24d86d28e2bee

    We used its fixed STReEF sample, pulse Gram arrays, selection, source metadata, and source retrieval code for a new reader comparison.

  3. usesdoi:10.18112/openneuro.ds005448.v1.0.0

    This is the STReEF dataset release used for the eight SEEG participants; the saved version-specific metadata identifies release 1.0.0 and CC0.

  4. doi:10.1016/j.ynirp.2025.100274
  5. doi:10.1007/s12021-022-09567-6

Cited by

0 publications

Public catalog entries on Sciscape.