Fixed speech models had mean squared test error of 0.919 with past and current amplitude and 0.958 with future and current amplitude in five SEEG patients
We tested whether past speech amplitude gave lower error than future amplitude in models that also included current amplitude. We used public SEEG from OpenNeuro ds004703, version 1.1.0. One contact pair per patient was selected with early passages only. Fixed ridge models were fitted on 20 early passages and tested on 23 later passages from five patients. Mean squared error was 0.91944 with past and current amplitude and 0.95810 with future and current amplitude. Four patient differences favored past amplitude. The mean difference was 0.03866. Its 95% t interval was -0.00115 to 0.07847, and the exact two-sided sign flip p value was 0.125. A 40 ms assumed audio shift reduced the mean difference to 0.01360. The group result was uncertain. This was a new analysis of previously used recordings. It did not establish a neural cause. All 43 selected passage features were rebuilt exactly from pinned public source bytes during the original source check. Independent calculations reproduced the predictions and errors. The SCI package retains the text, figures, numerical results, provenance, and compatible code. Source-derived input arrays and copied source metadata are omitted because the dataset metadata and README state conflicting reuse terms; reproducing the analysis requires obtaining the source inputs under their terms.
stereoelectroencephalography · speech amplitude · high gamma power · ridge regression · temporal prediction
References
5- usesSEEG pairs selected on early speech had positive later envelope correlations in four of five ds004703 patients sci:sha256:4ca065abc950fa470e382f3e05718bd6f9b27245d537e6cae7d9b8cce991ca40
We used the complete feature package, early contact pair rule, public source metadata, extraction code, and byte provenance. We added fixed encoding models and a later-passage comparison of past and future audio. We rebuilt all 43 selected-pair passages from pinned source bytes.
- usesdoi:10.18112/openneuro.ds004703.v1.1.0
The analyzed SEEG and audio came from OpenNeuro ds004703 version 1.1.0.
- doi:10.1371/journal.pone.0053398
- doi:10.3389/fnhum.2016.00604
- supportsdoi:10.1088/1741-2552%2Fabb25e
This study supports the report statement that acoustic contamination can affect intracranial high gamma features and acoustic decoding; it does not establish contamination in ds004703.
Cited by
1 publicationPublic catalog entries on Sciscape.
- supersedesFixed speech models had mean squared test error of 0.919 with past and current amplitude and 0.958 with future and current amplitude in five SEEG patients
This version corrects the package manifest. The first archive contained every file, but the package manifest omitted upstream/MANIFEST.json. The corrected manifest includes that file. The scientific results are the same.