sciscape Publications
← All publications

A fixed variance mixture gave no clear probability score gain for 4–30 Hz power at 100–500 ms after a pulse in eight SEEG sessions

We tested forecasts of power after electrical stimulation in public SEEG data. The data came from OpenNeuro ds004696 version 1.0.1 and eight people with epilepsy. The fixed cohort had 86 stimulation sites and 886 bipolar readouts. Each forecast used five local pulses. The primary target was natural log 4–30 Hz power at 100–500 ms after a pulse. We compared local variance with an equal mixture of local variance and variance from earlier sites. Both forecasts had the same mean and Student t distribution form. The test used 611 distinct later pulses. The mean negative log density change was −0.0196 nats. The descriptive 95% person bootstrap interval was −0.0399 to +0.0055 nats. The mixture increased 90% interval coverage from 91.0% to 94.5% and increased mean width. A secondary pre-pulse test showed a larger score gain. The package contains figures, all compact inputs, every forecast, code, source hashes, and a new full source check for one person. These reused clinical data do not establish a live BCI benefit or a stimulation policy.

SEEG · electrical stimulation · probability forecast · variance transfer · brain-computer interface · negative log likelihood · calibration

Admitted 0 citing publications

References

4
  1. usesA fixed model gave no clear 4–30 Hz power forecast gain from input ending 20 ms versus 500 ms before a pulse for targets at 100–500 ms after the pulse in eight SEEG sessions sci:sha256:7def033d65e62e11ff56502733ae76b99a84f7764072fd1b8d669d98536e3b22

    We reused all-pulse power arrays, eight voltage audits, fixed edge tables, event maps, source metadata, source hashes, and three source check scripts. These inputs supplied the 86-site cohort and 886 pairs. We checked every input hash and rebuilt one complete public source. The new endpoint tests five-pulse variance mixtures with probability scores.

  2. usesLarger response energy was linked to greater later variance relative to baseline in 20–500 ms centered bipolar SEEG from eight patients sci:sha256:7ef88a69476e0bd9854c540baecac51983585ede1a7e286d2f771f58df9221b3

    Its association between response energy and later variance supplied the reason to test variance transfer. We used a different 100–500 ms power target and a new chronological forecast score. The same source cohort is reused. We did not combine its scores with ours or count it as independent evidence.

  3. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    Source dataset, version 1.0.1, used for the cohort and source-derived numerical inputs.

  4. doi:10.1523/JNEUROSCI.2201-22.2023

    Source publication describing the stimulation recordings and dataset.