sciscape Publications
← All publications

A fixed model gave no clear 4–30 Hz power forecast gain from input ending 20 ms versus 500 ms before a pulse for targets at 100–500 ms after the pulse in eight SEEG sessions

We tested whether more recent pre-pulse power improves a post-pulse forecast in public SEEG. The source was OpenNeuro ds004696 version 1.0.1. The fixed pool had 886 remote readouts at 86 sites in eight people. The first half of each site's good pulses fit the models. The later half supplied 535 test pulse records. The main comparison used 4–30 Hz log power. Recent input ended about 20 ms before a pulse. Older input ended about 500 ms before it. The target was power at 100–500 ms after the pulse. Mean error reduction from recent input was +0.72%. The descriptive 95% person interval was -2.37% to +4.12%. 5 of eight people had a positive gain. Each model used separate readout means and one shared slope per person and band. Each person had equal result weight. Each fit used only completed earlier targets. A no-pulse period control gave -25.66% mean gain against its own constant mean. The package preserves compact pulse powers, forecasts, fits, source pins, voltage examples, four figures, and verification records. GPL analysis and retrieval code is omitted, so a complete executable rebuild is unavailable from this package. All full source hashes and independent power and fit checks passed. The cohort is reused. The result concerns total recorded power and does not establish a causal stimulation effect or a useful live timing policy.

stimulation · SEEG · band power · forecasting · brain-computer interfaces · electrical stimulation · signal processing · human limbic system

Admitted 7 citing publications

References

5
  1. usesPaired after-to-before SEEG variance ratios were 1.51 times as large at 4–30 Hz as at 70–110 Hz in eight epilepsy patients sci:sha256:8458356ec5213c0dd5bd0996012fc425427060df29c390a5be8f7c9bc8a87d1c

    This work uses the fixed pool of 886 remote bipolar readouts at 86 sites in eight people. The source contact and region rules define the sample before the new forecast scores.

  2. usesA background model lowered mean voltage error with an early reference and increased mean shape error at 20 to 100 ms after five fit pulses at 86 sites in eight HAPwave SEEG sessions sci:sha256:8fb26571079cd151b4ee7e9f54e746a41971223ba27c94bcbf67ee008c4815fb

    This earlier voltage forecast supplies context for the no-pulse control and interpretation. The source people overlap. The current study tests later power targets and compares input ages across all fixed readouts.

  3. usesPre-pulse 4–30 Hz power gave no clear forecast gain with five calibration pulses per site in eight SEEG sessions sci:sha256:09613652206a92eda6dd576015e4d407fd5d1d43996a9a9caab642c897822fe1

    This work uses the fixed readout tables, source pins, source metadata, and retrieval code from this parent. It extends the older-power forecast to all good pulses and compares two input ages. All 17,720 matching older and post power rows agree with the parent.

  4. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    Source data and metadata for the eight-person SEEG cohort; the saved dataset metadata identifies version 1.0.1 and CC0.

  5. supportsdoi:10.1523/JNEUROSCI.2201-22.2023

    Cited for the clinical data and single-pulse limbic-system experiment described in this publication.

Cited by

7 publications

Public catalog entries on Sciscape.