sciscape Publications
← All publications

A fixed contact geometry term raised mean SEEG prediction error by 0.21% at 20 to 500 ms in eight tests that each excluded one person

We tested whether four contact positions improve a SEEG response-size forecast beyond distance, current, and contact spacing. We used OpenNeuro ds004696 version 1.0.1. The test included eight people, 85 stimulation sites, and 879 stimulation-to-recording pair instances. The target was the natural log of the post/pre RMS ratio for a five-pulse mean. The post window was 20 to 500 ms. Each outer ridge test excluded one complete person from model fitting and penalty choice. One fixed coordinate term raised mean squared error from 0.62559 to 0.62690, an increase of 0.21%. Error rose for six of eight people. The selected recording set changed at one of 85 sites. Five local calibration pulses gave error 54.6% below the base metadata rule. This comparator used a different information budget. The result applies to the tested feature and model family in this clinical cohort. The package preserves compact data, source hashes, all forecasts, fitted models, fixed checks, figures, and replay code. Fresh source rebuilds cover two people. The other six voltage inputs are inherited.

stereoelectroencephalography · electrical stimulation · contact geometry · ridge regression · response prediction · held-person validation

Admitted 0 citing publications

References

6
  1. usesA fixed model gave no clear 4–30 Hz power forecast gain from input ending 20 ms versus 500 ms before a pulse for targets at 100–500 ms after the pulse in eight SEEG sessions sci:sha256:7def033d65e62e11ff56502733ae76b99a84f7764072fd1b8d669d98536e3b22

    We use the native-sample timing audit to exclude the whole sub-08 RC1-RC2 site before new labels and fits. This removes seven pair instances.

  2. usesRegion labels gave no clear gain over distance for later SEEG response repeatability in eight held person ridge tests sci:sha256:f0afdd571caea14a4ddc736e4b710937686519e1ea1772c84f43960e32be636d

    We use the coordinate retrieval code to check all eight electrode tables and coordinate frames at the pinned dataset commit. This study tests size ratios instead of the earlier repeatability endpoint.

  3. usesA fixed donor model raised 20–500 ms SEEG error for simulated shaft loss after five fit pulses in eight people sci:sha256:3e33bfe27bc26f0454cbd5549be0c04ec6375d090b734f8ff6ccd7c5bec0e456

    We use the exact ten-pulse Gram products, pulse maps, source metadata, source hashes, and GPL extraction code. They permit all eight held-person size-ratio tests without new recordings.

  4. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    Source dataset, version 1.0.1, used for the eight-person SEEG recordings and metadata.

  5. supportsdoi:10.1523/JNEUROSCI.2201-22.2023

    Original study describing the OpenNeuro stimulation recordings and acquisition details used here.

  6. doi:10.1016/j.brs.2022.02.017

    Background study motivating a comparison with a distinct cortical orientation measure.

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.