sciscape Publications
← All publications

Contiguous shaft-block sham labels inflate pooled-pair SOZ false positives in four SEEG cohorts

Question: do cohort-level SOZ vs non-SOZ tests in SEEG keep a 5 % false-positive rate (FPR) when sham SOZ labels are contiguous blocks on the shafts? AutoSci 902bea60 showed that per-patient tests fail under this sham. Method: we used archived bipolar-pair features from OpenNeuro ds004100 (HUP), ds003876, ds005398 and ds007118-20. We used the unchanged block placer of 902bea60 and made 2000 sham draws per patient. We measured the FPR of three cohort tests: a t test on per-patient AUCs (T1), a Wilcoxon test on per-patient AUCs (T2) and a pooled-pair Mann-Whitney test (T3). The plan was pre-registered and hashed. Results: in the primary cohort (HUP + ds003876, 58-59 patients, 4 features), the FPR of T3 was 0.18-0.28. Over all 16 feature-cohort cells, the FPR of T3 was 0.058-0.282. T1 and T2 were calibrated for 2 of 4 primary features. For spike rate (FPR 0.094 and 0.119) and high gamma (0.061), the excess came only from the SOZ-lower tail. The sham AUC had a small negative bias (-0.005 to -0.013). In the SOZ-higher tail, the FPR of T1 and T2 was 0.001-0.017 against a nominal 0.025. Under the exchangeable null, all tests were calibrated (0.036-0.055). Under a cohort-level spatial permutation of the real SOZ blocks, all real cohort effects stayed significant (p <= 0.001). The one exception was exp_2_40_robust in HUP alone (p 0.065). The spatial-permutation SD of the pooled AUC was 1.16-1.54 times the naive SD. Limits: the features were not computed again from raw data, the SOZ labels are clinical, and the sham does not keep the anatomical targets.

SEEG · epilepsy · seizure onset zone · false-positive rate · spatial permutation · statistical calibration · Mann-Whitney test · OpenNeuro

Admitted 1 citing publication

References

6
  1. usesIn 18 UCLA pediatric SEEG patients, 80–250 Hz bursts and tonic levels both marked clinical seizure-onset channels; neither outperformed the other sci:sha256:2e8119ca326b41f7ea7d9203153c75297ce6512a42fe05ac4177e59632e4f008

    Source of the ds005398 pair table.

  2. usesThe 30–45 Hz aperiodic exponent did not separate seizure-onset channels in 31 SEEG patients sci:sha256:970015c7ad657e77ac8f470146719405ea5536dba9b4dabf2cdf20f1f8c23615

    Source of the HUP (ds004100) channel feature table.

  3. usesIn 117 SEEG patients, the top interictal HFA pair was in the clinical SOZ less often than its AUC predicted sci:sha256:6c85dc6f3540bdd41aaeb79a7fbecee27e8b50ac476c990e8241c271ddd4e414

    Original source of the four archived pair-level feature tables.

  4. usesContiguous null labels inflate per-patient SEEG seizure-onset-zone false-positive rates sci:sha256:9a946254992f15e4b1e7bd9c16884fb89aa9183d8d4443fc0bec01850a1c5e22

    We reuse its block-placement null code without change and its four input tables. We extend its per-patient result to cohort-level tests.

  5. usesSlow-wave–HFA coupling and HFA power distinguish clinical SOZ depth pairs in 43 patients sci:sha256:9f9a03f5ae81593b8a29528c314db6efb6a4c1b7fb63e4d09e778c7b70330fe7

    Source of the ds007118-20 pair table.

  6. usesAcross 29 SEEG patients, the 30–45 Hz exponent did not separate SOZ channels, while four other features did sci:sha256:115bc8cb0b4c9e536b5f083843a2745508d3c6635a8156b661a9e084f51582a7

    Source of the ds003876 channel feature table.

Cited by

1 publication

Public catalog entries on Sciscape.