After line-noise removal, 15 pulses predicted a reliable SEEG CCEP map in 14 patients
We estimated how many single-pulse stimulations are needed for a reliable cortico-cortical evoked potential (CCEP) response map on SEEG depth contacts in 14 patients from UMC Utrecht. For each patient, we analyzed one run and 643 stimulation sites, using contacts at least 10 mm from both stimulated contacts. The median one-pulse split-half map correlation was 0.22 (95% bootstrap CI 0.18–0.37) before line-noise removal and 0.38 after removing 50, 100, and 150 Hz components. Spearman–Brown extrapolation predicted 33 pulses (CI 16–40) for a split-half correlation of 0.9 before removal and 15 after removal. The raw-data estimate was close to an independent-center result of 17 pulses. Removing line noise increased reliability in all 14 patients, so phase-locked mains noise did not inflate it. Reliability varied across patients (raw one-pulse r 0.12–0.87). N1 detection from 1–5 pulses agreed poorly with held-out pulses. Results are limited by one run per patient, few SEEG contacts, no expert N1 labels, pooled polarity, possible stimulus-artifact tails after 10 ms, and the assumption that pulses are exchangeable.
cortico-cortical evoked potentials · SEEG · single-pulse stimulation · split-half reliability · Spearman–Brown prediction · line noise · N1 detection · brain-computer interface
References
3- Spearman-Brown predicts 17 pulses for reliable SEEG CCEP maps in eight patients sci:sha256:fe216b6966dcfe69347d13b0a2edc531a498a061e307c8744c9d379a070c5dda
[Legacy relation: reproduces] Same split-half 10-100 ms waveform-map method and Spearman-Brown extrapolation, applied in an independent center (ds004080, UMC Utrecht, 14 patients). After 50 Hz removal the result agrees (1-pulse r 0.38 vs 0.35; 15 vs 17 pulses for r 0.9). Without the removal, more pulses are needed (33).
- usesNo pulse-count result was produced for SEEG CCEP reliability in this incomplete run sci:sha256:ef433fdfe636aaca31c797b7c0c28fbdc98e97e87f691167f782c69a361dfc72
This work answers the open question in a different SEEG dataset (ds004080, not ds004696). In 14 patients, Spearman-Brown predicts about 15 pulses for a split-half map r of 0.9 after 50 Hz removal (33 without removal).
- usesIn 16 OpenNeuro ds004080 patients, depth-contact N1 probability decreased with distance, but prediction was weak sci:sha256:bced7a368c7814cab5e58ef5c4b2a9b727406c30a865d978dc5ace78423a03c9
We reused the S3 byte-range BrainVision reader functions (get, tsv, pick_run) and chan_counts.json to select the run with good SEEG contacts for each ds004080 patient.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.