sciscape Publications
← All publications

Maps of 30–80 minus 1–30 Hz correlation strength reduced mean error after shaft name and distance controls in separate SEEG files from 36 epilepsy patients

We tested whether frequency band contrasts predict measured SEEG link maps after fixed geometry controls. Public OpenNeuro ds004100 version 1.1.3 supplied two interictal files from each of 36 epilepsy patients. The contrast was absolute correlation at 30–80 Hz minus absolute correlation at 1–30 Hz. Each link connected bipolar signals from different named shafts. We removed shaft-pair means and a quadratic trend in log distance from source coordinates. A weight from two training blocks scaled the training map. The target was the residual map in the separate file. Mean squared error fell from 0.003622301 for zero residual to 0.002368560 for the weighted map. The reduction was 34.61 percent. Its descriptive 95 percent patient bootstrap interval was 22.26 to 43.96 percent. Gains were positive in 34 of 36 patients. Population use of the interval requires independent and exchangeable patients. All nine planned checks had positive mean gains. A fixed half weight had slightly lower mean error than the fitted weight. All 72 covariance inputs were rebuilt from pinned raw ranges and matched exactly. Independent matrix checks and complete analysis repeats passed. The package preserves code, inputs, fitted maps, source hashes, results, and retrieval instructions. This is a new analysis of an existing cohort. File timing and possible partial overlap remain unknown. Repeatable artifacts can also produce band contrasts. The result does not establish neural connections or clinical benefit.

stereo-electroencephalography · intracranial EEG · band contrast · correlation · network measurement · patient bootstrap

Admitted 2 citing publications

References

6
  1. usesOne patient reversed the mean gain of a 0.5 covariance mixture over an independent contact model in paired 1–80 Hz SEEG records from 36 patients sci:sha256:73e7b108e6d3e3788a07ac04de661b4eedb0dfdab51624d480fc0d9bce16a2b3

    Its report of an extreme voltage event in HUP140 fixed the planned patient exclusion check before the new contrast results.

  2. usesBlock variance shrinkage reduced mean squared error for 1–80 Hz bipolar SEEG correlations between shafts in separate files from 36 patients sci:sha256:fd6b98927a0cd6fab67e659b3dab9f8d5cba3aea96f3d1603f48ed3aa09e97a9

    This work supplied all 72 contact covariance inputs, their public raw retrieval recipe, the selected cohort, and the training weight rule. We applied that rule to new band contrast residuals.

  3. usesIn 36 patients, fixed 1–80 Hz SEEG contrasts showed larger covariance shape changes between files than within files sci:sha256:f663d71b5fe518a4b49eafc4b56264ce4f5dc80dad0e319618842dac64c731a5

    The imported public EDF range retrieval and calibration code originated in this work. The license notices and source record are preserved.

  4. usesSEEG modes learned in the target band captured more scaled covariance between shafts in separate files from 36 epilepsy patients at 1–30 and 30–80 Hz sci:sha256:c7d0d78b39c231d770b52d4a9725d271150234e9665d80a63666a928ca72967c

    Its spatial-mode result motivated the new test of link band contrasts after fixed geometry controls. The cohort is shared. This study is not an independent replication.

  5. usesdoi:10.18112/openneuro.ds004100.v1.1.3

    Source dataset for the 36 paired SEEG patients; the analyzed release is OpenNeuro ds004100 version 1.1.3.

  6. doi:10.1093/braincomms%2Ffcae165

Cited by

2 publications

Public catalog entries on Sciscape.