Hippocampal high-gamma load effects did not repeat across sessions in 14 patients
We tested whether per-patient working-memory load effects in hippocampal stereo-EEG (SEEG) repeat across sessions. We analyzed archived per-trial features from OpenNeuro ds004752 (version 1.0.1): 14 epilepsy patients, 48 sessions, and 1,908 correct, clean trials. Features were Spearman correlations between memory set size (4, 6, 8) and response time or maintenance-minus-fixation log power. For high gamma (70–150 Hz), the session-stratified group effect was a small decrease (weighted z = −0.074, SE = 0.024). Between-patient spread was not greater than sampling noise (I² = 0; 95% upper limit for tau = 0.103), and split-half reliability was near zero (r = 0.01). Gamma, beta, and the spectral exponent showed the same lack of measurable spread and repeatability. With about 75 trials per half, the noise SD of a per-patient z was about 0.13; about 213 trials per half would be needed for r = 0.7 if high-gamma tau were at its upper limit. The underlying task-related feature changes were more stable across halves (r = 0.37–0.79). Session-stratified response-time effects varied between patients (I² = 0.48, p = 0.025), but split-half reliability was not significant (r = 0.40, p = 0.074). Alpha showed a candidate split-half correlation (r = 0.55, p = 0.024) that did not survive Holm correction (p = 0.19). Calibration found that the planned pooled-trial Q test was not valid for response time (false-positive rate 0.19); session-stratified estimates were calibrated. These results do not support using the load contrast as an individual marker with 1–4 sessions and this trial count. Limits include 14 patients, one hippocampal shaft per patient, short analysis windows, and epilepsy patients.
hippocampus · stereo-EEG · working memory · high gamma · test-retest reliability · measurement noise · epilepsy
References
3- usesIn 14 patients, fixation-corrected hippocampal high gamma decreased weakly with load (Holm p = 0.035); new sessions 3–4 were not significant (p = 0.15) sci:sha256:acf14f56bd0bdcd727e6aaf77c5c50a8b7962d6a78ebebad8526450f813e0141
We use the archived per-trial hippocampal band-power features of this package as input, and we test if its per-patient load effects are stable across sessions.
- usesdoi:10.18112/openneuro.ds004752.v1.0.1
The archived per-trial features analyzed here derive from OpenNeuro ds004752 version 1.0.1; the saved dataset metadata identifies this exact release and records CC0.
- doi:10.7554/eLife.78677
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.