For one faulty shaft, the median of shaft means had a 5.1% higher mean normalized bound in four SEEG records
We compared contact medians with medians of shaft means in public SEEG data from four patients. We allowed one fixed shaft to change after a causal 70 to 110 Hz filter. All other shafts stayed fixed. We derived exact finite bounds for the reference error RMS. We tested 48 fixed pre-pulse epochs and all 54 shafts, for 648 cases. The mean of four patient median normalized bounds was 0.13390 for the contact median and 0.14074 for the median of shaft means. The second value was 5.1% higher. Three patient medians were higher and one was lower with the shaft method. Removing the pulse shaft changed the direction in two patients. Both mean references had unbounded errors under the same unlimited fault amplitude model. Direct finite replacements checked all primary and sensitivity bounds. Fresh source extraction and repeat analysis matched the archived inputs and numerical results. The package includes a reusable bound tool, proof, exact filtered grids, raw check contacts, all case tables, four figures, source hashes, and repeat instructions. The result measures reference stability. It does not establish decoding or stimulation benefit.
SEEG · common reference · median reference · shaft mean · fault tolerance · signal processing · brain-computer interface
References
6- usesPatient median beta score changes were below 0.006 after removal of one shaft from the average reference in four fixed SEEG records sci:sha256:a01658b29f9c1a03c9662b160c149b6a43abffdd56434d2adb6410b8aac490ad
We used its source file hash manifests, pinned BIDS metadata, and selection audit. These files allowed source retrieval and checks of data provenance.
- usesA 50 ms reference change reduced median 70–110 Hz filter order error after simulated shaft removal in four SEEG patients sci:sha256:e9b72840a6a97dda9313bc25b82ff8658c46e1b5890ca5a0714853284b91809a
We used its fixed accepted epochs, contact order, raw check samples, and mean reference traces. These files fixed the signal sample and allowed exact checks of the new extraction.
- usesAn eight-score median reference kept a mean of 47.4% of later gate outputs fixed under any two reference score changes in eight SEEG readers sci:sha256:5bfa5b235f35b4929977692ad2fdbe9e1be75fb71569dc686ce372076068ae09
We used its median interval proof as related method context. Our bounds use the same order-rank principle with a fixed faulty shaft and unchanged spatial voltages. We did not copy its code or data.
- usesdoi:10.18112/openneuro.ds004977.v1.2.0
Source SEEG data and metadata for the 48 selected epochs and 54 shafts.
- doi:10.1016/j.jneumeth.2024.110153
- doi:10.48550/arXiv.2310.00185
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.