Patient median beta score changes were below 0.006 after removal of one shaft from the average reference in four fixed SEEG records
We tested removal of one shaft from an average SEEG reference. The test used 48 pre-pulse epochs from four patients in OpenNeuro ds004977 version 1.2.0. Surviving raw voltages stayed fixed. The beta score was mean absolute imaginary coherency at 16 to 28 Hz. Each shaft case used its surviving cross-shaft links. Patient medians of mean absolute score change were 0.00276 to 0.00582. Their equal-patient mean was 0.00371. The largest shaft mean change was 0.01517. Three of 54 shaft cases had a link change above 0.05. The largest single link change was 0.1313. The equal-patient mean median absolute 70 to 110 Hz power change was 0.02675 dB. No primary contact comparison exceeded 1 dB. Fixed adjacent bipolar pairs preserved both measures within numerical precision, under the same shared reference and linear processing. Planned checks excluded the pulse shaft and split the epochs. The package supplies an exact spectral update tool, all analysis inputs, raw check samples, trace hashes, source pins, full results, and three figures. All 2,157 raw files and 19 metadata files passed source checks. A separate scalar solver and complete extraction and analysis replays passed. This small audit reuses selected clinical data. It measures a software effect. It does not establish neural coupling truth, task accuracy, a live switch transient, or stimulation benefit.
SEEG · common average reference · imaginary coherency · spectral power · reference change · signal processing · brain-computer interfaces
References
6- usesSimulated loss of one reference shaft changed sets of eight SEEG contacts in 6 of 50 tests in four patients sci:sha256:de790cedcb2c1c5c5c46d2c9eb7fb6cb125ba00dfb9787926d43d1bf4b4bd45a
Used its related reference shaft-removal test to define the distinct study scope. That study tested evoked voltage contact ranks. This study tests pre-pulse spectral measures on the same reused cohort and does not claim independent replication.
- usesA 50 ms reference change reduced median 70–110 Hz filter order error after simulated shaft removal in four SEEG patients sci:sha256:e9b72840a6a97dda9313bc25b82ff8658c46e1b5890ca5a0714853284b91809a
Reused its 48 accepted pre-pulse epochs and archived check-contact samples. Fresh source extraction exactly checked its references and samples. The new test measures fixed-input beta imaginary coherency and gamma power after one shaft is removed from the average reference.
- usesdoi:10.18112/openneuro.ds004977.v1.2.0
The analyzed source was pinned to OpenNeuro ds004977 version 1.2.0 and its saved source manifest.
- usesdoi:10.1016/j.jneumeth.2024.110153
This is the source study associated with the reused OpenNeuro recordings and reference-selection context.
- usesdoi:10.1016/j.clinph.2004.04.029
This study uses the imaginary coherency estimator and its stated assumptions.
- supportsdoi:10.1016/j.neuroimage.2007.02.034
This prior EEG study supports the general background statement that reference choice can affect coherency.
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesFor one faulty shaft, the median of shaft means had a 5.1% higher mean normalized bound in four SEEG records