Pair coding gave higher later balanced state accuracy than contact coding with early fixed readers and ranges at a uniform 64-bit sample budget in eight SEEG recordings

At a uniform 64-bit sample budget, coding eight pairs gave 70.29% mean later balanced accuracy. Coding their contacts gave 54.17%. The readers and voltage ranges were fixed from early trials. The paired mean difference was 16.12 percentage points. Its descriptive 95% person bootstrap interval was 9.95 to 22.53 points. The test used eight public SEEG recordings in OpenNeuro ds004473 version 1.0.2. The labels were rest and before response. Each person had a separate reader. Fitting readers again to coded data reduced the pair advantage to 4.55 points. Pair coding kept accuracy near the source result, but five later buffers had a flat clipped pair. Those cases increased probability loss. The package contains exact contact samples, code, source pins, readers, all fixed comparisons, figures, and repeat instructions. This is an exploratory digital replay. It does not test a new ADC, live control, or stimulation.

stereo-EEG · brain-computer interface · signal coding · balanced accuracy · contact pairs · quantization

Admitted 2 citing publications

References

5
  1. usesFiltering before fourfold sample removal gave 70.6% mean balanced accuracy in later trials from eight SEEG recordings sci:sha256:8bc11c5e9496aba0a89fbf8535edb5ce1336d5a00cc9df2b9795ddfb7b8ddde4

    This package supplied the exact native pair samples, early readers, trial choices, source headers, and pinned EDF ranges. We used them to retrieve and check the distinct contact samples.

  2. usesZero-centered 8-bit waveform codes reduced frozen SEEG task-state accuracy from 70.7% to 50.6% in eight recordings sci:sha256:f11a99582db0d0fff28986ef433b9cde1661cb1668cb5772f0a78262582c2b8c

    This study supplied the prior evidence on fixed-centered bipolar voltage coding. It set the pair-code comparison and showed why coding before contact subtraction needs a separate test.

  3. usesEight SEEG pairs classify pre-response and rest windows at 70.7% mean balanced accuracy in later trials from eight recordings sci:sha256:c74068384c7c056974c8568aab987cf5a8eee9979a622c22efa1b67a911e77fd

    This study supplied the original early pair choices, retained trial definitions, source event windows, and EDF range helper code. We kept its choices and archived its records.

  4. usesdoi:10.18112/openneuro.ds004473.v1.0.2

    The exact-version OpenNeuro ds004473 1.0.2 SEEG recordings, events, and channel metadata supplied the analyzed inputs.

  5. doi:10.1088/1741-2552%2Facae0a

Cited by

2 publications

Public catalog entries on Sciscape.