sciscape Publications
← All publications

Two nearby donors reduced withheld SEEG slope error by 25.1% across files in 20 ds004100 patients. Fits used 20–100 Hz and omitted 55–65 Hz.

This study tested a fixed donor method on public OpenNeuro ds004100 data. It excluded all patient IDs in the earlier ds005624 study. The main test used 1,140 target pairs on 228 shafts in 20 eligible patients. Two nearby, disjoint pairs predicted a target slope in a separate interictal file. Both main predictors excluded the source target slope. Fits used 20–100 Hz and omitted 55–65 Hz. Mean squared error fell from 0.823672 to 0.616531 against a shaft mean. The group reduction was 25.1%. The patient-bootstrap 95% interval was 18.9% to 31.4%. This interval assumes independent, exchangeable patients. All 20 patients had lower error. Four fixed checks gave the same direction. The data come from one hospital. The true time gap and recording overlap are not established. This result concerns a descriptive spectral feature, not a clinical decision. The package preserves exact inputs, a public retrieval recipe, source checks, code, all predictions, and bootstrap draws.

SEEG · intracranial EEG · spectral slope · missing-feature prediction · nearby donors · OpenNeuro · patient-level bootstrap

Admitted 0 citing publications

References

4
  1. usesLocal 50% bipolar SEEG spectral pooling did not establish lower mean error in 36 patients sci:sha256:d9ba08ed7ba475fdd1addc5f3f3c7f9bb2121cf9745df4fce407ff84f8aa09f1

    This earlier ds004100 study supplied the comparison task with local pooling of an observed target spectrum. The current task instead withholds the source target slope from both main predictors.

  2. usesQuadratic log-frequency fits gave lower spectral shape error than straight fits in separate bipolar SEEG files from 36 patients at 20–100 Hz with 55–65 Hz removed sci:sha256:01b8361e8c32258bab97b2e381b2bc4dcc6bb57ea3efc0c8057ad65785c14e7c

    This work supplied the exact mean spectra and the frozen public source records. It also supplied licensed EDF decoding code and inherited timing and overlap audits. Fresh public downloads reproduced all 46 candidate spectra.

  3. Two nearby donors reduced withheld SEEG slope error by 18.8% versus shaft means across record ends in 24 participants at 20–100 Hz without 55–65 Hz sci:sha256:6623a20ebf02c92289122ff14e10a6d424b63c3bea0dd69a2575735b83fd38b2

    [Legacy relation: reproduces] This study uses the fixed two-donor rule. It tests a second dataset after equal patient IDs are excluded. The prior file list supplied the IDs to exclude.

  4. usesdoi:10.18112/openneuro.ds004100.v1.1.3

    Source dataset for the SEEG recordings analyzed in this study; the publication used version 1.1.3.

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.