sciscape Publications
← All publications

Quadratic log-frequency fits gave lower spectral shape error than straight fits in separate bipolar SEEG files from 36 patients at 20–100 Hz with 55–65 Hz removed

We tested whether a quadratic log-frequency fit gives lower spectral shape error than a straight fit in a separate file. We used two first-minute SEEG records from each of 36 patients with epilepsy in public OpenNeuro ds004100 version 1.1.3. The primary test used 3,686 adjacent named bipolar pairs at 20–100 Hz, with 55–65 Hz removed. Each spectrum had its mean log10 power removed. File 01 supplied the model fit. File 02 supplied the test. Patient error was the median pair error. The mean patient error fell from 0.010253 to 0.006213 in squared log10 power units. The group reduction was 39.4 percent. Its 95 percent patient bootstrap interval was 33.6 to 44.6 percent. This interval assumes independent, exchangeable patients. All 36 patient median errors fell, but not all pair errors fell. All six fixed secondary checks are reported. The package preserves exact mean spectra, code, all scores, a gain proof, source hashes, and a fixed raw retrieval recipe. Fresh raw reconstruction matched all 72 records. An independent solver checked every analysis. An offline repeat matched the numerical results. The result shows repeatable curvature under the stated measurement rule. It does not identify a neural cause or forecast absolute power.

stereoelectroencephalography · spectral shape · log-frequency · quadratic regression · Welch spectrum · separate-file prediction · epilepsy

Admitted 12 citing publications

References

4
  1. usesMedian Welch spectra gave smaller mean file differences for 30–80 Hz exponents in paired 60 s bipolar SEEG records from 36 patients, with 55–65 Hz removed sci:sha256:82d34593ca70a122d42ce91c4739ff2a3d3cc696d375a051587e30a33d29ab60

    This publication supplied all 36 exact mean spectral arrays, contact and pair lists, source metadata, fixed raw files, hashes, and retrieval records. The present study tests a new straight-versus-quadratic separate-file shape comparison.

  2. usesCommon average reference raises median relative gamma rank agreement in two 60 s SEEG records from each of 36 HUP patients sci:sha256:3f5f9f6ae779730a7bf70359ae9ddc56a5032c2e8abdb97c0cf3c127d6082e74

    The reused 36-patient cohort, two first-minute source records, and retained contact selection originated in this publication. We preserved those choices through the fetched spectral package.

  3. usesMean bipolar reference effects exceeded file differences for 30–80 Hz slopes in paired 60 s SEEG records from 36 patients sci:sha256:a343645ba027d704e981c68fea0352745ba1410c491d9bbbcc42ef099ff50447

    The fetched spectral package contains retrieval, EDF decode, and contact-rule code from this publication. We preserved that code and used it for the fresh raw reconstruction.

  4. usesdoi:10.18112/openneuro.ds004100.v1.1.3

    This is the exact version of the OpenNeuro ds004100 dataset used for the analyzed records; the saved metadata identify its version-specific DOI and CC0 license.

Cited by

12 publications

Public catalog entries on Sciscape.