Task history reduced prediction loss for three memory loads in test SEEG sessions from 14 patients at penalty 10
We tested task history and hippocampal power as predictors of four, six, and eight letters in public SEEG data. We used OpenNeuro ds004752 version 1.0.1 and exact reused feature arrays from 14 patients with epilepsy. Separate multinomial logistic models trained on the earlier half of numeric session labels and tested on the remaining sessions. The main penalty was 10. There were 1,312 training trials and 1,506 test trials. History lowered mean patient test log loss by 0.048898. The 95 percent patient bootstrap interval was 0.021955 to 0.071156, and Holm-adjusted sign-flip p was 0.009277. Thirteen patients had lower loss. Adding six mean hippocampal power bands during late maintenance increased loss by 0.088680 at penalty 10. At penalty 100, the interval included zero. The source task audit found five exceptions to the stated after-error load rule; no labels were repaired. This exploratory study supplies a control model and a reproducible probability benchmark. It does not show that hippocampal load information is absent. The package preserves source pins, exact inputs, code, fitted parameters, predictions, patient scores, bootstrap draws, raw checks, and repeat instructions. All 62 sessions passed selected fresh raw-window checks. Three full sessions passed exact feature rebuilds. All 34 numerical outputs matched an offline repeat.
SEEG · memory load · task history · hippocampus · log loss · multinomial logistic regression · cross-session prediction
References
4- usesAdding hippocampal theta contact differences increased mean load prediction error across excluded sessions from 13 SEEG patients at ridge penalty 10 sci:sha256:faac1a461991224ef6bdbf9e4e2a34f4d0dae88581bc1af12639542913c8f905
The prior fixed across-session load prediction result informed the study context and the need to state model limits. Our target, loss, history inputs, and split differ. Its fitted models and test scores did not enter the new fits. Its full report is preserved for comparison.
- usesMean hippocampal fixation theta power density decreased more than a fixed spectral trend after errors at load four in 14 epilepsy patients sci:sha256:e79f76d88dc1468b3801b5d292228dc657eb4ca1255530107b7bf8fe34f5c216
This work supplies 62 exact feature archives, public metadata, source object pins and full raw hashes, and the unchanged extractor. We add fixed three-class probability models with task history and compare them in separate numeric session halves. These are the same patients, not an independent replication.
- usesdoi:10.18112/openneuro.ds004752.v1.0.1
Source dataset, exact version used to identify the analyzed public session data; its recorded CC0 metadata is preserved.
- supportsdoi:10.7554/eLife.78677
Source article documents the task periods and reported after-error load rule described in this study.
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesTask history had lower mean memory load prediction loss than history with fixation power subtraction in session tests from 11 epilepsy patients
We used its unchanged SEEG feature arrays, pinned source hashes, metadata, extraction code, and data and model-check helpers. Its fixed-penalty results set the question for this new baseline comparison.
- usesMean normalized test error increased with a previous trial theta input in 12 SEEG patients at penalty 10
This archive supplies the exact 62 power feature files, public metadata, source pins, extraction receipts, and three unchanged source-check scripts. Its task-history analysis informed the control inputs. We test prediction of the next fixation theta power with an added past-power input. The patients are reused.