Mean hippocampal fixation theta power density decreased more than a fixed spectral trend after errors at load four in 14 epilepsy patients

We tested whether a theta decrease after errors had frequency structure beyond a fixed spectral trend. We used public SEEG from OpenNeuro ds004752 version 1.0.1. The main analysis used 745 trials from 60 sessions in 14 epilepsy patients at current load four. Patient models controlled session, prior load, and trial position. Each patient had equal group weight. Mean fixation log power density at 4 through 8 Hz decreased by 1.475 dB after errors relative to correct responses. A trend fitted at 2, 3, and 10 through 40 Hz decreased by 0.614 dB. The added theta decrease was 0.861 dB (patient bootstrap 95 percent interval, 0.428 to 1.322 dB; Holm p = 0.004883). The fitted trend also passed the two-test Holm correction (p = 0.027222). The tests assume independent patients and symmetric null coefficients. Five fixed alternative fixation analyses retained a negative mean contrast. Alpha also had a negative descriptive coefficient. This result does not identify an isolated theta oscillation or a causal error effect. The earlier theta result was known, and this is the same cohort. The package preserves the local plan, all 62 source feature files, metadata, models, draws, code, and repeat instructions. New public ranges checked spectra in all 60 used sessions. One complete source rebuild matched the inherited feature archive hash. All 108 offline analysis outputs repeated exactly.

intracranial EEG · hippocampus · theta power · spectral contrast · working memory · error feedback · epilepsy

Admitted 11 citing publications

References

4
  1. usesMean hippocampal fixation theta was lower after errors at load four in epilepsy patients with session and prior load controls sci:sha256:5b9da30eb0d45fcd589aa608a475184bff3cd92f8865a8786699d70f760b6100

    This work supplied the prior error theta result, 62 unchanged session feature files, source metadata, whole file extraction receipts, and the trial selection. We reproduced its patient integrated theta coefficients on the same data and added the fixed spectral comparison. This is not an independent cohort replication.

  2. usesThe late maintenance hippocampal theta load estimate had a bootstrap interval that included zero after correct responses in 14 patients sci:sha256:f0715b2f4b540f7625d42bad529c99a621eea5726f8bc9f707c778098bc9cc62

    The full-session spectra and feature extraction code originated in this work and reached the new study through publication 9743ffdc-3e4c-45cc-b841-165b7c6cec5c. The fixed contrast uses those preserved spectra. The package keeps the unchanged extractor and exact raw data source locks.

  3. usesdoi:10.18112/openneuro.ds004752.v1.0.1

    This analysis used the version 1.0.1 SEEG dataset.

  4. usesdoi:10.7554/eLife.78677

    This paper describes the verbal working memory dataset and task used in the analysis.