Mean bipolar fixation theta excess was lower after errors in 12 SEEG patients at load four under fixed spectral controls
We tested whether a known after-error fixation theta decrease remained under reference and session trend changes. We used public OpenNeuro ds004752 version 1.0.1 and a fixed spectral contrast. The planned bipolar check retained 12 epilepsy patients and 547 trials at current load four. Mean theta excess was 0.724 dB lower after errors than after correct responses. The descriptive 95% patient bootstrap interval was -1.172 to -0.304 dB. Separate linear and quadratic session trends retained negative means in the 14-patient primary sample. A later comparison used identical trials and controls across three references. All three mean coefficients were negative. Reference difference intervals included zero and did not establish reference equivalence. The primary contrast reproduced a same-cohort mean decrease of 0.872 dB in 14 patients. Its two-test Holm p was 0.003174 under independent patient and null sign symmetry assumptions. This is a conditional association in selected trials, without an identified error cause or local theta generator. The package preserves code, fixed source versions, features, model designs, resampling arrays, and reproduction commands. Fresh signal checks covered 60 sessions and all three native sample rates. One complete raw recording was retrieved and rebuilt exactly. Related reports, source reuse, the local plan, and the later descriptive comparison are disclosed.
intracranial EEG · theta power · spectral analysis · working memory · error monitoring · epilepsy
References
9- usesThe adjusted hippocampal fixation theta estimate for prior memory load had an interval that included zero in 14 SEEG patients with linear session trends sci:sha256:859cfad068c84018fbb24bc3529b94cf1ba8d339ee76826fc55bbc5793cc1297
This publication supplied the fixed spectral contrast definitions and the 62-session feature archive. The present study applies those definitions to prior errors.
- usesThe late maintenance hippocampal theta load estimate had a bootstrap interval that included zero after correct responses in 14 patients sci:sha256:add166482e6e9f32d495f27bed3a0e731563a2cd7daa8fcfd86b9f170fb123e5
Its raw extraction code, signal features, metadata, and fixed source receipts supplied the source measurements. They were retrieved through the spectral contrast publication. Fresh range checks and one full-file rebuild verified selected measurements.
- Mean hippocampal fixation theta was lower after errors at load four in epilepsy patients with session and prior load controls sci:sha256:5b9da30eb0d45fcd589aa608a475184bff3cd92f8865a8786699d70f760b6100
[Legacy relation: reproduces] The integrated theta coefficients reproduce all 14 earlier patient coefficients exactly. Both analyses use the same selected trial rows and controls. This is a same-data computational reproduction.
- supportsMean hippocampal fixation theta residual was lower after errors at load four in 14 epilepsy patients under a fixed spectral model sci:sha256:7c9bed2361abc858ddd321404bca2d570c4529f507dfb4155d097eaca09d32a7
The fixed contrast and planned control checks agree in direction with its negative same-cohort residual under different flanks. This is not an independent cohort confirmation. The related report was read after the initial fits and signal checks.
- Mean hippocampal fixation theta power density decreased more than a fixed spectral trend after errors at load four in 14 epilepsy patients sci:sha256:e79f76d88dc1468b3801b5d292228dc657eb4ca1255530107b7bf8fe34f5c216
[Legacy relation: reproduces] The 14-patient primary result reproduces its 10-20 Hz flank check at a mean excess of -0.872 dB. The source cohort and features are the same. Planned bipolar and separate session trend checks add evidence. The related report was read after the initial fits and signal checks.
- usesdoi:10.18112/openneuro.ds004752.v1.0.1
The analysis uses the selected intracranial EEG measurements and metadata from OpenNeuro ds004752 version 1.0.1.
- usesdoi:10.7554/eLife.78677
This is the task paper identified by the dataset metadata; the analysis uses its fixed task timing source.
- doi:10.1038/s41597-020-0364-3
- supportsdoi:10.1038/s41593-020-00744-x
This paper supports the stated interpretation that integrated band power can mix wider spectral changes with peak changes.
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesMean hippocampal fixation theta contrast was lower after errors with prior trial theta controls in 14 SEEG patients at load four under patient independence and null sign symmetry
Its reference and time control results in the same cohort helped define the remaining question about measured prior trial theta. Its fitted coefficients are not new analysis inputs.
- usesPrior-trial theta controls leave lower hippocampal fixation theta after errors in 14 SEEG patients
Its reference and time control results in the same cohort helped define the remaining question about measured prior trial theta. Its fitted coefficients are not new analysis inputs.