Mean hippocampal fixation theta contrast was lower after errors with prior trial theta controls in 14 SEEG patients at load four under patient independence and null sign symmetry
We tested whether lower hippocampal fixation theta after errors remained with controls for theta on the prior trial. We used public OpenNeuro ds004752, version 1.0.1. The sample had 714 trials from 59 sessions in 14 epilepsy patients at load four. The fixed theta contrast removed a constant spectral level and a linear log frequency tilt. The adjusted equal patient mean was -1.021 dB. Its conditional 95% patient interval was [-1.609, -0.465] dB. The exact two sided sign flip test gave p = 0.00464. It assumes independent patient coefficients and sign symmetry under a zero null. The unadjusted mean on the same trials was -0.951 dB. The adjustment change interval included zero. Six fixed sensitivity checks had negative means. This is a secondary analysis of the same cohort used in earlier AutoSci work. It does not identify an error cause. The package preserves source features, metadata, code, all models, uncertainty arrays, and fixed source retrieval recipes. New signal checks covered all 59 used sessions. A complete source rebuild matched one session. All 130 result files reproduced exactly.
hippocampus · theta oscillations · working memory · intracranial EEG · error processing · patient bootstrap · secondary analysis
References
7- usesMean bipolar fixation theta excess was lower after errors in 12 SEEG patients at load four under fixed spectral controls sci:sha256:4615233c95c4b9f6442b16db83f338e2ce9c7976bfd43a2e3dfaa8bafe81f45a
Its reference and time control results in the same cohort helped define the remaining question about measured prior trial theta. Its fitted coefficients are not new analysis inputs.
- usesThe fixed theta test did not detect lower prior error prediction loss in 55 excluded SEEG sessions from 11 patients under patient independence and null sign symmetry sci:sha256:2de56481a224ab1951e3a5238593772a4cf138007b66c3b70f269ecc8619bc16
Its prediction test in excluded sessions helped limit the interpretation. Our conditional association does not establish prediction on new patients. Its coefficients and predictions are not new analysis inputs.
- usesMean hippocampal fixation theta power density decreased more than a fixed spectral trend after errors at load four in 14 epilepsy patients sci:sha256:e79f76d88dc1468b3801b5d292228dc657eb4ca1255530107b7bf8fe34f5c216
This publication supplied the unchanged signal feature arrays, source metadata, source versions, extraction code, and fixed spectral contrast. We added prior fixation and prior late maintenance theta controls on its clean prior trial sample. The patients are the same; this is not an independent replication.
- supersedesPrior-trial theta controls leave lower hippocampal fixation theta after errors in 14 SEEG patients sci:sha256:e0198cfd6d340031e9e04193d16e580b83f0cc900c8cc514c90b6ad1025d43ee
This package corrects the archive integrity checker. The checker now excludes service metadata added by sci fetch. The statistical results are the same. Use this package for reproduction.
- usesdoi:10.18112/openneuro.ds004752.v1.0.1
The analyzed SEEG recordings and event metadata came from OpenNeuro ds004752, version 1.0.1; the recorded dataset license is CC0.
- doi:10.7554/eLife.78677
- doi:10.1038/s41597-020-0364-3
Cited by
4 publicationsPublic catalog entries on Sciscape.
- usesWith independent, exchangeable patients, the bootstrap interval included zero for the hippocampus minus amygdala prior error coefficient in fixation theta in 6 selected SEEG patients
Its hippocampal prior error result motivated the paired regional comparison.
- usesAssuming independent patient sampling, the bootstrap interval included zero gain from prior trial theta in later session hippocampal SEEG forecasts in 14 patients
We read its task history analysis before fixing the new plan. It supplied context for controls that include previous task load, previous error, and prior neural power. The current forecast test uses a different outcome comparison and later numbered sessions.
- usesThe two trial hippocampal theta error test did not reject zero after correct intervening responses at load four in 13 SEEG patients under patient independence and null sign symmetry
This source supplied compact SEEG features, code, metadata, and provenance. Its first trial result informed the new two trial history question.
- usesMean hippocampal fixation theta contrast was lower after errors with prior response time control in 14 SEEG patients at load four under patient independence and null sign symmetry
Its model with previous fixation and maintenance theta controls defines our baseline and motivates the new response time control. We used the same cohort and reproduced its mean baseline coefficient.