In 43 SEEG patients, spike-ripple rate did not outperform spike rate for clinical SOZ pairs in 90 s NREM recordings
We compared interictal spike rate with the rate of spikes that had a co-occurring 80–250 Hz ripple in 43 epilepsy patients (728 bipolar SEEG pairs, 160 clinical seizure-onset-zone [SOZ] pairs, about 90 s of interictal NREM sleep per patient). The spike-ripple rate and spike rate had the same mean per-patient AUC (0.764); their difference was −0.0004 (95% CI −0.043 to 0.040; p = 0.99). The CI excludes a gain larger than 0.04 AUC for these detectors and data. The fraction of spikes with a ripple was higher in SOZ pairs (mean AUC 0.714), but did not outperform spike rate. A strict detector variant showed the same pattern. The data were taken from OpenNeuro ds007118, ds007119, and ds007120, version 1.0.0; all 43 EDF byte-range hashes matched the archived values. This study used short recordings and automatic amplitude detectors without visual review. It assessed clinical SOZ labels, not surgical outcome, and does not test visually reviewed events or long recordings. The findings do not prove equivalence.
spike-ripples · interictal spikes · seizure-onset zone · SEEG · epilepsy · NREM sleep · AUC
References
4- usesSlow-wave–HFA coupling and HFA power distinguish clinical SOZ depth pairs in 43 patients sci:sha256:9f9a03f5ae81593b8a29528c314db6efb6a4c1b7fb63e4d09e778c7b70330fe7
We used its patient set, bipolar pairs, clinical SOZ labels, EDF byte ranges with SHA-256 values, and its archived 80-300 Hz log power per pair. We re-read the same bytes and verified all 43 hashes.
- usesdoi:10.18112/openneuro.ds007118.v1.0.0
Provides three of the 43 patients and the SEEG data used in this analysis (OpenNeuro version 1.0.0).
- usesdoi:10.18112/openneuro.ds007119.v1.0.0
Provides part of the 43-patient SEEG cohort used in this analysis (OpenNeuro version 1.0.0).
- usesdoi:10.18112/openneuro.ds007120.v1.0.0
Provides part of the 43-patient SEEG cohort used in this analysis (OpenNeuro version 1.0.0).
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesSpike rate and high-frequency activity did not show patient-level complementarity in 39 NREM SEEG patients
Archived per-pair spike rate and 80-300 Hz log power (results/pairs.tsv).
- supportsAutomatic spike rate distinguishes SOZ pairs from clinically spiking non-SOZ pairs, but spike-ripples add no separation
In the harder SOZ vs irritative-zone contrast, spike-ripples again did not separate SOZ pairs better than all spikes.
- usesAutomatic spike rate distinguishes SOZ pairs from clinically spiking non-SOZ pairs, but spike-ripples add no separation
We used its archived per-pair spike, spike-ripple and ripple counts and its label table.