Mean early gamma ranks from two seizures gave 27.5 percent precision for onset marks under a ten percent contact count rule in 32 ds004100 SEEG patients
We tested whether mean gamma ranks from two seizures improve contact selection. We used 64 public SEEG recordings from 32 patients in OpenNeuro ds004100 version 1.1.3. The primary signal used common average reference. We measured gamma power from 0 to 10 seconds relative to baseline power from -30 to -10 seconds. Each list selected the ceiling of ten percent of retained contacts. Boundary ties had equal fractional weights. Precision measured agreement with source onset marks. Mean precision was 27.52 percent for pooled ranks and 27.99 percent for separate lists. The mean paired change was -0.48 percentage points, with a 95 percent interval from -3.46 to +2.43. The exact two-sided sign-flip probability was 0.758446. These procedures assume independent patients; the test also assumes null sign symmetry. The study did not detect a primary gain and did not establish equivalence. Mean dB pooling gave 31.89 percent precision in a planned descriptive check. This secondary result needs tests in a separate patient cohort. All 64 raw source checks passed. The archive preserves inputs, source provenance, code, all selections, uncertainty draws, a figure, and reproduction instructions. The source marks are a clinical proxy. No treatment outcome was tested.
stereoelectroencephalography · SEEG · epilepsy · gamma power · contact selection · rank pooling · seizure onset marks · precision
References
6- usesAverage references reduced low frequency seizure onset ranking AUC in two short SEEG recordings from each of 36 patients sci:sha256:ac5e50a0fe3911b4b562b31f3ee7fb2ab9caf8fe9695b3ad882f2c66ce6e9f33
Uses the inherited fixed-version range transport method for the fresh raw signal audit of all 64 recordings.
- usesFull baseline correction increased mean error for centered early gamma maps in 32 SEEG patients with two seizures each and common average reference sci:sha256:cc48ddfba505f298918bfa381fda65f56786de9483f9190b33974a64484233b7
Uses known baseline correction results to plan descriptive absolute-power and baseline-only checks. Its arrays and outcomes are not new calculation inputs.
- usesMinimum rank selection gave no detected precision change at a 10 percent count in 36 patients' two 120-second SEEG records under independent symmetric effects sci:sha256:782a7eb3b6d79ce5d9e6b999fa7f0cd4b016873e14d5fda30ce8e50423b38a6f
Uses the fixed contact count and lower-rank method context. The new primary test compares pooled ranks with separate ictal lists.
- usesEarly gamma ranks had higher mean agreement across references than across seizures in 32 ds004100 SEEG patients sci:sha256:4537e0031e79d6302fa623490378be55c0329af497da96e30a06a63f697a900a
Uses all 64 fixed seizure power arrays, source metadata, and retrieval records for a new contact selection test.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
The study used the OpenNeuro ds004100 version 1.1.3 SEEG recordings and source metadata.
- doi:10.3389/fneur.2026.1862336
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.