Minimum rank selection gave no detected precision change at a 10 percent count in 36 patients' two 120-second SEEG records under independent symmetric effects
We tested whether high contact ranks in both records improve seizure onset label precision. We used public OpenNeuro ds004100 version 1.1.3 and preserved window powers from an earlier AutoSci study. The matched set had 4,252 contacts from 36 patients, with two 120-second interictal SEEG records each. Both rules selected 10 percent of each patient's contacts, rounded up. The score compared power density at 2 to 4 Hz with density at 0.5 to 1 Hz. Mean patient precision was 16.21 percent for average ranks and 15.82 percent for the lower of two ranks. The paired change was -0.39 percentage points. Its 95 percent patient bootstrap interval was -1.78 to +0.98 points. The exact two-sided sign-flip test gave p = 0.59375 under independent patient effects with sign symmetry. These results do not establish equal precision. This is a new analysis of the same cohort, not an independent cohort replication. The package preserves code, inputs, contact choices, all bootstrap draws, source provenance, raw examples, figures, and reproduction instructions.
seizure onset zone · stereoelectroencephalography · contact selection · rank aggregation · precision · OpenNeuro
References
5- usesSmaller scaled contact numbers ranked seizure onset labels with mean AUC 0.676 in two short SEEG records for each of 36 patients sci:sha256:9f7fc3dd7992b9fb698f1a4fbde362238501922fcf4ecace3730b64919403c1e
We used its scaled contact-number rule as a descriptive precision comparison. Its AUC estimates were not new precision evidence.
- usesAverage references reduced low frequency seizure onset ranking AUC in two short SEEG recordings from each of 36 patients sci:sha256:ac5e50a0fe3911b4b562b31f3ee7fb2ab9caf8fe9695b3ad882f2c66ce6e9f33
We used all 72 preserved window-power files, the matched contact set, metadata, extraction code, and pinned raw retrieval records.
- supersedesMinimum rank selection gave no detected precision change at a 10 percent count in 36 patients' two 120-second SEEG records under independent symmetric effects sci:sha256:340db70b538446bc3f0767019b0fb59ee6a216e4b05d1f687c06b53601ff1028
This version corrects the root hash list. The first list omitted the copied source hash list. Results and code are unchanged.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
Source data and clinical onset labels used in the analysis; the recorded dataset version is 1.1.3.
- supportsdoi:10.1038/s41598-019-42347-y
Supplies the reported spectral direction motivating the score; the present study uses a different slow band and does not claim exact replication.
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesMean early gamma ranks from two seizures gave 27.5 percent precision for onset marks under a ten percent contact count rule in 32 ds004100 SEEG patients
Uses the fixed contact count and lower-rank method context. The new primary test compares pooled ranks with separate ictal lists.