A complete power bound prevented releases with error above one percent of early mean power after 10 ms gaps filled with zero in 35 SEEG records from 21 patients under a missing voltage cap

We tested a power error gate after missing SEEG voltage. The study used 35 public records from 21 patients and four fixed channels per record. Each simulated gap was filled with zero. The main test used nominal 10 ms gaps, causal 70 to 110 Hz band voltage, and a 100 ms power mean. The error limit was one percent of an earlier mean power. A proof gave a bound for the complete feature under an absolute cap on missing voltage and equal state before the gap. All main missing samples met the selected cap. The complete gate had no above-limit releases in the 500 ms output interval. A gate for the current squared signal had a bad release rate of 0.465 percent of all output opportunities. The descriptive patient bootstrap interval for the paired reduction was 0.358 to 0.578 percentage points. The complete gate accepted 34.926 percent of outputs; the current gate accepted 49.387 percent. Each patient had equal weight. The package contains the proof, streaming reference code, all selected voltage, source hashes, public retrieval code, counts, checks, and four figures. All 35 selected records matched a fresh source rebuild. A second analysis produced 16 byte-identical result files. The voltage cap is an external assumption. This test did not measure decoding, live stimulation, or clinical safety.

causal signal processing · power error bound · missing data · stereoelectroencephalography · SEEG · brain-computer interfaces · streaming algorithms

Admitted 1 citing publication

References

3
  1. usesA 1 mV RMS error model gave 128–178 ms guards for a causal 70–110 Hz filter in five SEEG recordings sci:sha256:2c4619c59bc30f32e3bd9cc14c155e6bd363a5bfae302a15788d0c12105ad785

    This prior method supplied the causal voltage error guard problem after missing input. The present method uses an absolute sample cap and extends the error calculation through the square and moving power mean. No analysis code or voltage data from that publication were used.

  2. usesA complete saved state reproduced causal power after restarts in 35 SEEG records with no input gaps sci:sha256:d4cdf85cce272a8a687213150339eac50e9e6430ca265dbcef84cd2277e3810c

    This publication supplied all 35 selected voltage records, the public source and metadata manifests, the metadata files, and the retrieval code. These inputs enabled the independent gap and power gate test. The new test extends the earlier complete-input restart problem to unknown missing voltage.

  3. usesdoi:10.18112/openneuro.ds006519.v1.0.0

    The study analyzes the 35 selected SEEG records from this exact OpenNeuro dataset version; the saved version-specific metadata records CC0.