A 1 mV RMS error model gave 128–178 ms guards for a causal 70–110 Hz filter in five SEEG recordings

We derived an upper bound on later output error after a finite input error in a causal filter and evaluated it on 400 pulse epochs from five patients in OpenNeuro ds004457 version 1.0.2. The filter was a causal fourth-order Butterworth band-pass design (total band-pass order eight) from 70 to 110 Hz at 2048 samples per second. Under the stated model, two inputs differed only during [0,10) ms, their prior filter states were equal, and the input error RMS over the 21-sample gap was at most 1 mV. For each epoch, the output error limit was its measured pre-pulse band-voltage RMS. The sufficient guard times ranged from 128.4 to 178.2 ms, with a median of 163.6 ms; a 20.020 ms guard failed the limit in every epoch. After each calculated guard, the bound was no greater than the epoch baseline RMS in every later 62-sample window. A permitted error shape produced 352.5 microvolts RMS in the window starting at 20.020 ms. For past-sample replacement, the bound covered all 786,400 measured later-window differences, and fresh raw extraction matched all 3,276,800 archived digital samples. The guards are sufficient limits for the declared mathematical error model, not measured neural recovery times. The 1 mV budget and 10 ms interval are assumptions. The analysis reuses a published cohort and adds no independent patients.

causal filtering · signal processing · error bounds · stereoelectroencephalography · SEEG · brain-computer interfaces · pulse artifact

Admitted 6 citing publications

References

4
  1. usesBipolar subtraction changed site accuracy in both directions at 30–100 ms in five SEEG sessions sci:sha256:531e50239e932801e1c0cfd358414615addc29385833c8f1831bb538445b2800

    We used its fixed ventral temporal contacts, pinned source manifest, and MIT raw retrieval recipe through the later extraction package. We preserved its code license and verified all 30 raw file hashes.

  2. usesReplacing pulse samples changed zero-phase 70–110 Hz SEEG voltage above baseline RMS at 20–50 ms in 27/400 pulses (five patients). sci:sha256:78299ccd5493ea3f4d9c8ec1dfad43bf77ec6ab49d467ba2f55a3b7b4806dddd

    We reused its fixed 400 pulse epochs, contact scales, source metadata, event selection, and raw extractor. Fresh source extraction matched all arrays. The new work adds an arbitrary input error bound and an all-later-window guard. It does not add independent patients.

  3. usesdoi:10.18112/openneuro.ds004457.v1.0.2

    The analyzed 400 pulse epochs and source metadata are from OpenNeuro ds004457 version 1.0.2.

  4. supportsdoi:10.1523/JNEUROSCI.1325-22.2023

    This is the source study for the five-patient SEEG cohort and stimulation recordings used in the analysis.