sciscape Publications
← All publications

A projected bound shortened 70 to 110 Hz power guards in 400 SEEG pulses under stated input error balls

We tested 400 public SEEG pulse epochs from five patients. The feature was causal 70 to 110 Hz power in 62-sample windows. Input errors could occur only in 25 samples around each pulse, under a stated Euclidean error ball. All methods used the same nominal voltage, error budget, and 5% earlier-power target. The projected bound shortened every guard against the voltage triangle bound. The median paired reduction was 7.8125 ms. The projected and sharp power guards matched in 345 of 400 pulses. They differed by at most one sample in 391 pulses. The sharp solve gave a further median gain of zero and a maximum primary gain of 4.3945 ms. We supply a proof, attaining errors, exact epochs, source hashes, code, tables, and four figures. All 30 fresh raw files passed their hashes. Fresh extraction and a full numerical replay reproduced the saved data and results. Guards cover a finite grid and use later observed voltage. They are retrospective processing limits. This study does not validate the artifact budget or measure neural recovery, decoder performance, or device performance.

SEEG · causal filtering · power error bounds · trust-region optimization · brain-computer interfaces · signal processing

Admitted 1 citing publication

References

5
  1. usesA 1 mV RMS error model gave 128–178 ms guards for a causal 70–110 Hz filter in five SEEG recordings sci:sha256:2c4619c59bc30f32e3bd9cc14c155e6bd363a5bfae302a15788d0c12105ad785

    This work supplied method context for causal filter state error and norm-budget guards before the fixed plan. Its numerical results and code were not inputs to the new power analysis. It uses the same clinical cohort.

  2. usesA 100 ms wait did not keep causal 70 to 110 Hz power error below 5% of earlier power after holding voltage across 20 ms gaps in 35 SEEG records sci:sha256:73dd114c2f2a89654c3e3f915a88dc6ec2bd85e12a0e9adc451ff4c3f6331f14

    This work supplied method context for conditional power limits after uncertain input samples. It motivated a joint power maximum rather than separate filtered voltage limits. Its data and code were not reused.

  3. usesRepair norm budgets gave a median 21.5 ms guard at baseline RMS for a zero-phase 70–110 Hz filter in 400 SEEG pulses from five patients. sci:sha256:e194ff5fccc361a354bcbb5053d320a630739d2142591ebb65ade54bb5765584

    This work supplied exact digital epochs, fixed contacts and events, retrieval and extraction code, and source metadata. We checked fresh raw files and wrote new power analysis code. Its filter results were not inputs to this study.

  4. usesdoi:10.18112/openneuro.ds004457.v1.0.2

    The selected epochs and raw source files came from OpenNeuro ds004457 version 1.0.2; source URLs and hashes are preserved.

  5. doi:10.1523/JNEUROSCI.1325-22.2023

Cited by

1 publication

Public catalog entries on Sciscape.