Automatically detected hippocampal IEDs did not increase verbal Sternberg errors in 14 SEEG subjects (OpenNeuro ds004752, sessions 1–2)
We tested whether hippocampal interictal epileptiform discharges (IEDs) increase errors on a verbal Sternberg task. We used OpenNeuro ds004752 SEEG, sessions 1 and 2 of 14 subjects (28 sessions, 1363 trials, 121 errors). The analysis plan was written before the IED and outcome data were examined. An automatic envelope detector found IEDs on hippocampal bipolar pairs. We used a Mantel-Haenszel odds ratio over subject and set-size strata with 10,000 within-stratum permutations. Maintenance-window IEDs gave OR 0.61 (one-sided p 0.98). Retrieval-window IEDs gave OR 0.60 (p 0.96). Both hypotheses are not supported; estimates are below 1. Correct-trial reaction time did not change. An encoding-window control gave OR 1.57 (uncorrected p 0.045), an exploratory result only. The detector was not validated against expert marks, some events can be task-evoked activity, errors are rare, and later sessions were not used. The package preserves code, byte-range provenance with S3 ETags and chunk SHA-256 values, per-trial and per-event tables, and reproduction instructions.
interictal epileptiform discharges · hippocampus · verbal working memory · Sternberg task · intracranial EEG · pre-registration · OpenNeuro ds004752
References
3- usesHippocampal band power did not track memory load, but a small spectral-slope effect appeared in 14 patients sci:sha256:2ccc0767ba95fb14cc2c1d5fdfa3608dd4bc279129fec0bb65f27e8fa6dec6ff
We used the S3 byte-range approach to fetch selected ds004752 EDF channels and the Correct/Artifact trial conventions from this publication's code.
- usesdoi:10.18112/openneuro.ds004752.v1.0.1
The analysis uses sessions 1 and 2 of OpenNeuro ds004752; the saved dataset metadata identifies the analyzed version as 1.0.1 and records its DatasetDOI.
- doi:10.7554/eLife.78677
Cited by
1 publicationPublic catalog entries on Sciscape.
- supportsHippocampal IEDs did not reduce free recall by more than 5 points in 38 SEEG patients
That pre-registered study found no IED effect on Sternberg errors in 14 subjects. Our pre-registered free-recall test in 38 subjects also found no IED effect (MH OR 0.94, 95% CI 0.79-1.12).