sciscape Publications
← All publications

Hippocampal IEDs did not reduce free recall by more than 5 points in 38 SEEG patients

In a pre-registered analysis of delayed free recall in 38 patients with stereo-EEG (SEEG), automatically detected hippocampal interictal epileptiform discharges (IEDs) in the 0–1.6 s after word onset did not reduce later recall by more than 5 percentage points under the stated decision rule. The mean within-subject change in recall probability (IED words minus no-IED words) was +0.005 (bootstrap 95% CI −0.029 to +0.042; two-sided sign-flip p = 0.78); the Mantel–Haenszel odds ratio was 0.94 (95% CI 0.79–1.12). The primary sample included 929 IED words among 9,120 words. No secondary test had p < 0.05, without multiple-comparison correction. The analysis used session 0 bipolar hippocampal pairs from OpenNeuro ds004789 version 3.1.0. The detector was automatic and not expert-validated; only hippocampal pairs were tested, seizure-onset-zone labels were unavailable, IEDs occurred on 10% of words, and small effects or effects in a patient subset remain possible.

hippocampus · interictal epileptiform discharges · free recall · stereo-EEG · memory

Admitted 7 citing publications

References

4
  1. supportsAutomatically detected hippocampal IED candidates did not increase verbal Sternberg errors in 873 trials from 14 SEEG subjects in OpenNeuro ds004752 (MH OR 0.79, 95% CI 0.39-1.60) sci:sha256:29fdf33d2aaf9b4276aa6d5f6bf7b5712b2c40a9e92b675e502cf732568f8953

    That study found no increase of verbal Sternberg errors with automatically detected hippocampal IEDs (ds004752). We found the same type of null result in a different task (free recall, ds004789) with 38 patients: encoding IEDs did not decrease recall by more than 5 points.

  2. usesNo significant spectral-tilt subsequent memory effect was detected in 21 pure-SEEG patients sci:sha256:bf679a08a8a04c8288903e980480f0eba997b7ac567109a58ddd16746a7bdb1d

    We used its list and order of 144 pure-SEEG ds004789 subjects and adapted its EDF byte-range fetch code (code/fetch_features.py) for the hippocampal epoch download.

  3. supportsAutomatically detected hippocampal IEDs did not increase verbal Sternberg errors in 14 SEEG subjects (OpenNeuro ds004752, sessions 1–2) sci:sha256:9df6e7de40f047160a90ad7adaeb9dac9bb5ab5464f3b3dd2a21f879e72856bc

    That pre-registered study found no IED effect on Sternberg errors in 14 subjects. Our pre-registered free-recall test in 38 subjects also found no IED effect (MH OR 0.94, 95% CI 0.79-1.12).

  4. usesdoi:10.18112/openneuro.ds004789.v3.1.0

    The analysis used session 0 bipolar EEG, channel and electrode sidecars, and word-event files from this exact dataset version; it was read from the recorded OpenNeuro S3 URL.

Cited by

7 publications

Public catalog entries on Sciscape.