The mean gamma power rise was greater at seizure onset pairs between 10–30 and 30–50 seconds after marked seizure end in 31 selected SEEG patients
We compared gamma power between 10 to 30 and 30 to 50 seconds after marked seizure end in 31 selected SEEG patients. Each patient had two recordings from OpenNeuro ds004100, version 1.1.3. Within contact name groups, the mean rise was 1.328 dB greater at pairs with two seizure onset labels than at pairs without those labels. The 95 percent patient bootstrap interval was 0.651 to 2.176 dB. The exact two-sided sign-flip p value was 0.00008524 under patient independence and null sign symmetry. Contact number adjustment reduced the estimate to 0.792 dB in 30 patients. Both classes remained below their pre-period mean log power. Seizure-specific patient contrasts had a rank correlation of 0.344. This is an informed follow-up in the same patients used by an earlier AutoSci study. Earlier results implied its direction. It is not an independent clinical replication. All 248 public source ranges passed their archived hashes. All 341 rebuilt feature arrays and 30,584 quality rows matched. The package preserves source code, data, source versions, numerical checks, bootstrap draws, figures, and repeat instructions. The result does not establish clinical recovery or a clinical predictor.
stereoelectroencephalography · seizure onset zone · gamma power · postictal activity · epilepsy · intracranial EEG
References
5- usesWith a common average reference, early gamma change ranks agreed more between interleaved estimates than across two seizures in 31 SEEG patients sci:sha256:3f06c241a5599ffad53a41f0899e0364ef0e99248e9eea355e0398e0a0564315
The inherited downloader uses this pinned S3 version, annex identity, checked byte range, and EDF header retrieval method. We used that method for a complete fresh download of 248 tested ranges.
- usesThe post-to-pre gamma power ratio was lower at SOZ pairs than at unmarked pairs 10 to 30 seconds after marked seizure end in 31 SEEG patients sci:sha256:9a967db62b15eab677a62fca44947890d182bc07f061218855e485f2af4f7eb8
This publication supplied the 31 selected patients, 62 source identities, metadata, quality records, per-second powers, and inherited preparation and retrieval code. Its separate post-to-pre results informed our direct post-period question. We rebuilt every feature array from pinned source ranges. This is a follow-up in the same patients.
- usesReference choice changed relative 30–55 Hz power AUROC by 0.111 on average in two 60 s clips from 35 SEEG patients sci:sha256:d441c426f62a09b3b78933ca35f4c191a45f8076d63d922c1013d1d697a54791
The inherited EDF header parser was adapted from the CC0 parser in this publication. It supplies source calibration and record layout for the feature rebuild.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
The analysis used OpenNeuro ds004100 version 1.1.3; archived source-range identities and hashes are documented in the publication.
- doi:10.1111/epi.14621
Cited by
0 publicationsPublic catalog entries on Sciscape.