Clipped trial products reduced geometric mean squared forecast error for later 20–500 ms SEEG energy estimates in eight sessions

A fixed clipped trial-product estimator forecast later SEEG response energy with less error than squared mean voltage. We used public OpenNeuro ds004696 version 1.0.1 from eight epilepsy patient sessions. At each of 86 stimulation sites, the first five good pulses supplied forecasts and the final five supplied a signed trial-product target. The tested window was 20 < t < 500 ms. There were 886 bipolar readout edges and 430 unique later physical pulse events. Each edge loss was scaled by early mean single-pulse energy squared. Readouts, sites, and patients received nested equal weights. The geometric patient MSE ratio was 0.783, a 21.7% reduction; the patient bootstrap 95% interval was 0.653–0.925. Six patients had less error and two had more error. The exact two-sided patient sign-flip p value was 0.0390625 under independent, sign-symmetric patient effects. Clipped energy and energy of a scaled voltage forecast had almost equal error. Before stimulation, zero had less error than clipping. The result concerns a later measured energy estimate within a session. A stable mean and independent zero-mean trial noise are needed to interpret it as mean response energy. The study did not test neural origin, behavior, stimulation safety, or online BCI benefit. The package preserves trial products, all forecasts and losses, three figures, source hashes, code, and reproduction instructions.

stereoelectroencephalography · trial products · response energy · forecast error · electrical stimulation · brain-computer interface

Admitted 0 citing publications

References

6
  1. usesFour-pulse noise correction reduced forecast error for later SEEG energy estimates in three of five patient sessions sci:sha256:1617e96e4206c4b038b54ea68b75bb824c73ca6ed35d2019c4d81cd24ea4c3ef

    This study tests the earlier exploratory clipping proposal with a fixed analysis in a different public dataset. It uses five early and five later pulses in ds004696, rather than the earlier four-pulse ds004457 design.

  2. usesFive-pulse noise scaling reduced later single-pulse error for 20–500 ms centered bipolar SEEG in eight patient sessions sci:sha256:fbc06ab469d48eac7a6f54dd97cd24ccd9c7c5ca4b0db4d64340536b3e81428a

    The exact trial products, contact rules, corrected chronological event mapping, source metadata, and extraction code define the eight-patient inputs. The new outcome is later signed trial-product energy rather than single-trial voltage waveform loss.

  3. usesA five-pulse check selected more repeatable bipolar SEEG pairs within eight epilepsy patient sessions sci:sha256:b5b7963746f5c6d2a2a8f7844ec590732a4eb152bc7a70979b3bc95c3e27820f

    This source established the public bipolar trial product derivative and extraction rules reused through the voltage parent. The present study uses all retained edges without its response acceptance threshold.

  4. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The analyzed SEEG derivative inputs are from OpenNeuro ds004696 version 1.0.1; their URLs and hashes are preserved.

  5. doi:10.1523/JNEUROSCI.2201-22.2023
  6. doi:10.1371/journal.pcbi.1011105

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.